8
PRESET LONG BLACK
There are 3 preset Long Black settings - small, medium and large.
To use one of these settings:
1. Fill the portafilter using the auto grind, dose & tamp function.
2. Insert the portafilter into the group head.
3. Position your cup so the portafilter spouts and hot water outlet are
directed inside the cup (see fig. 9 ).
4. Rotate the LONG BLACK dial to the desired size.
5. Press the LONG BLACK dial.
NOTE
Pressing the LONG BLACK dial during the espresso extraction will stop the
flow of espresso and start the flow of hot water. Pressing the LONG BLACK
dial during the hot water delivery will stop the flow of hot water.
TIP
There are 6 custom settings for you to program. Once programmed, your
custom settings will appear after the 3 preset settings. Refer to the ‘Long
Black Adjust Programming Custom Settings’.
MANUAL LONG BLACK
During manual Long Black mode, the LCD will show a moving cup icon.
• Press and hold LONG BLACK dial to activate pre-infusion. Release
LONG BLACK dial to commence espresso pour.
• Press the LONG BLACK dial to stop espresso pour and commence hot
water pour.
• Press the LONG BLACK dial again to stop the pour of hot water.
HOT WATER
The HOT WATER button can be used to pre-heat cups or add hot water
manually. To stop and start the pour of hot water, press the HOT WATER
button and hot water will cease to dispense after approx. 30 seconds.
Press again if more needed.
NOTE
You cannot run hot water and extract espresso at the same time.
PROGRAMMABLE FUNCTIONS
To enter program mode, press the MENU button. Rotate SELECT dial to
the desired function.
Program mode allows you to program:
• Shot Volume
• Shot Temperature
• Clean Cycle
• Set Clock
• Auto Start
• Auto Off
• Tamp Set
• Pre-Infusion
• Long Black Adjust
To exit program mode, press MENU button.
SHOT VOLUME/DURATION
• Grind coffee beans and insert the portafilter into the group head.
• While ‘SHOT VOL is displayed on the LCD, rotate the SELECT dial to
‘1 CUP’ or ‘2 CUP’ to reprogram the desired selection. Press the
SELECT dial to start espresso extraction. When required volume/duration
has been extracted, press SELECT dial to stop extraction. Machine will
beep once to confirm.
SHOT TEMPERATURE
While ‘SHOT TEMP’ is displayed on the LCD, press the SELECT dial.
The current temperature will flash. Turn the SELECT dial to required
temperature then press SELECT dial to set. Machine will beep once
to confirm.
CLEANING CYCLE
The cleaning cycle cleans the shower screen and back-flushes the group
head, Select this feature when the LCD displays ‘CLEAN ME!’
Refer to ‘Cleaning Cycle’.
SET CLOCK
Setting the clock is optional. While ‘SET CLOCK’ is displayed on the LCD,
press the SELECT dial. Turn the SELECT dial to the left or right to adjust
time, and then press the SELECT dial to set. Machine will beep once
to confirm.
AUTO START
• Auto Start is optional. It allows you to program the specific time when the
machine will automatically turn on. While ‘AUTO START’ is displayed on
the LCD, press the SELECT dial. Turn the SELECT dial to ‘On’ or ‘Off’.
Press SELECT dial to set.
• Turn the SELECT dial to the left or right to select the desired Auto Start
time. When the required time has been reached, press the SELECT dial
to set. A small clock icon will be displayed on the LCD when the Auto
Start function has been programmed.
TIP
We recommend programming the machine to start 30 minutes before you
plan to use it.
AUTO OFF
This function sets how long the machine will stay turned on before it
automatically turns off. It can be set for 5 mins, 10mins or 20mins until
Auto Off activates. While ‘AUTO OFF’ is displayed on the LCD, press the
SELECT dial. Turn the SELECT dial to the desired time then press SELECT
dial to set. Machine will beep once to confirm selection.
TAMP SET
• Adjusting tamp parameters allows for fine tuning of coffee tamping force
and polishing duration. While ‘TAMP SET’ is displayed on the LCD, press
the SELECT dial. The tamp force setting will flash. Turn SELECT dial to
setting 1-9.
• Press SELECT dial to set and the current polishing time will flash.
Turn SELECT dial to select 2-10 seconds. Press SELECT dial to set.
Machine will beep once to confirm settings.
PRE-INFUSION
This function is for advanced use only. While ‘PRE INFUSE’ is displayed
on the LCD, press the SELECT dial. The pump power setting will flash.
Turn SELECT dial to increase or decrease the pre-infusion pressure.
Press SELECT dial to set and pre-infusion duration will flash.
Turn SELECT dial to adjust seconds. Press SELECT dial to set.
Machine will beep to confirm settings.
LONG BLACK ADJUST PROGRAMMING CUSTOM SETTINGS
There are 6 custom Long Black settings for you to program to suit your cup
size and strength preferences. To program your custom setting:
1. Fill the portafilter using the auto grind.
2. Insert the portafilter into the group head.
3. Position your cup so the portafilter spouts and hot water outlet are
directed inside the cup.
4. Press the MENU button. Rotate the SELECT dial to ‘LONG BLACK
ADJUST’ then press the SELECT dial.