manualshive.com logo in svg
background image

4

 SL6+ v.3.30 EN

Introduction

This unit was built with state-of-the-art technology and to 

generally recognised safety related technical standards currently app-

licable. These installation instructions are to be followed by all people 

working with the unit, in both installation and maintenance.

It is extremely important that these installation instructions are made 

available at all times to the relevant technicians, engineers or servicing 

and maintenance personnel. The basis prerequisite for safe handling 

and trouble free operation of this system is a sound knowledge of the 

basic and special safety regulations concerning conveyor technology, 

and elevators in particular. The unit may only be used for its intended 

purpose. Note in particular that, no unauthorised changes or additions 

may be made inside the unit or individual components.

Exclusion of liability

The manufacturer is not liable with respect to the buyer of this product 

or to third parties for damage, loss, costs or work incurred as a result of 

accidents, misuse of the product, incorrect installation or illegal chang-

es, repairs or additions. Claims under warranty are likewise excluded in 

such cases. The technical data is the latest available. The manufacturer 

accepts no liability arising from printing errors, mistakes or changes.

Declaration of conformity

Download ”The declaration of conformity” at our website: 

www.safeline-group.com

Safety Precautions!

 - Only trained professionals, who are authorised to work on the equip-

ment, should install and confi gure this product.

 - This quality product is dedicated for the lift industry. It has been 

designed and manufactured to be used for its specifi ed purpose only. 

If it is to be used for any other purpose, SafeLine must be contacted in 

advance.

 - It should not be modifi ed or altered in any way, and should only be 

installed and confi gured strictly following the procedures described in 

this manual.

 - All applicable health and safety requirements and equipment 

standards should be considered and strictly adhered to when installing 

and confi guring this product.

 - After installation and confi guration this product and the operation 

of the equipment should be fully tested to ensure correct operation 

before the equipment is returned to normal use. 

Electrical and electronic products may contain materials, parts and 

units that can be dangerous for the environment and human health. 

Please inform yourself about the local rules and disposal collection 

system for electrical and electronic products. The correct disposal of 

your old product will help to prevent negative consequences for the 

environment and human health.

General

information

Содержание SL6+

Страница 1: ...afeline group com 01 2019 2019SafeLine andall the SafeLine productsand accessoriesarecopyrightedby law Compliesto EN81 28andEN81 70standards PATENT08163634 2 Lift EmergencyTelephone SL6 v 3 30EN SL6 M...

Страница 2: ...e CONNECT 17 ParametersuniqueforSafeLineCONNECT 18 ConfigurationwithPC 19 Configurationwithtelephone 20 Remoteconfigurationwithtelephone Step1 21 Remoteconfigurationwithtelephone Step2 22 On siteconfi...

Страница 3: ...arge 13 65VDC max 200mA Emergencylight Emergency lightoutput 12VDCmax500mA Emergencysignal Acousticemergencysignaloutput 12VDCmax200mA Inputs 10 30VDC 5mA opticallyisolated Antennaconnector SMA female...

Страница 4: ...ufacturer acceptsno liabilityarisingfromprintingerrors mistakesorchanges Declaration of conformity Download The declarationofconformity atourwebsite www safeline group com SafetyPrecautions Onlytraine...

Страница 5: ...etweenmainunit and stations The bus systemconsistsoffourwires twofortransfering voiceanddata and two forpowersupply Usethe adressselectorto setauniqueadressforeachstation ranging from 1 6 It is import...

Страница 6: ...indicators a Mainspower b Activealarm battery status c PSTN GSM netcallstatus 4 USBMini BPCconnection Forfirmware updateand configuration 5 RS232PCconnection For configuration 6 Screw terminal for opt...

Страница 7: ...e13 Screwconnectorterminals Emergency light Isconnectedwith Cable13 Hearingloop Isconnectedwith Cable13 RS232PCconnection Forfirmwareupdate TerminalRJ45 Input output busconnection powerand externalpic...

Страница 8: ...2 7 8 SL6 v 3 30EN Installation 1 Addressselector Fixed valuesetto 1 carunit 2 Connections 3 Pictogramoutput 4 Additionalalarm button N O 5 RS232PCconnection 6 Volumecontrol 7 Emergencylight onlyforS...

Страница 9: ...stablesurface eg wall controllercabinet usingappropriate screws Noterminationresistanceisneededattheendsofthebus To avoid GSM interference placethemainunit thestationsandthe GSMantennaatleast1 5meter...

Страница 10: ...lay 1 Common Relay 1 N C Relay 1 N O Phone line Phone line Bus 12 VDC Bus GND Bus A Bus B Battery 12 VDC Battery 0 VDC 12 VDC Input 2 configurable Input 1 configurable Emerg bell Emerg bell Emerg ligh...

Страница 11: ...ither SafeLine Pro or CONNECT N O default or N C Parameter 89 please refer to the corresponding code in the Parameter List Grey Orange Black Red Yellow Green Blue Brown Input B not in use Input A alar...

Страница 12: ...above It s possible to connect up to nine SL6 main units to the same telephone line In order to access the unit remotely it needs to be assigned a unit number Please refer to parameter 82 in the Param...

Страница 13: ...akeacallfromyourphonetoverifythattheSIMcardisactive 4 Makea calltotheSL6 afterinsertiontoensurethereisaproper connection 1111 PINcode IfthePINis setto 1111 thecodewillberandomlygeneratedbythe SafeLine...

Страница 14: ...ous red Batterytestfailure nobattery connected LED2indicates activealarm and batterycondition Flashinggreen 100 100ms Fire mode activated Flashinggreen 400 400ms Callconnectioninprogress Slowlyflashin...

Страница 15: ...llowLED GreenLED Light off Noalarmactivated TelephonelinenotOK Flashingslowly Flashing onceevery5seconds Telephone line notOK Flashingonceevery5seconds UnitisOK Flashingquickly Flashing twiceeveryseco...

Страница 16: ...ne lineisconnectedoraGSMnetis available LED3isflashinggreen every5seconds 6 Refer to chapter Trouble shooting main unit Example foundallvoice stations exceptfornumber3 Startup procedure Connect230VAC...

Страница 17: ...nfigure all the functions for voice stations in and outputs etc Simulate alarms Here it is possible to simulate an alarm battery failure callback stuck button etc Main unit diagnostics See current sta...

Страница 18: ...built inmagnetbutton In and outputs Relay1 2 Emergencybuttoncheck During emergencybuttoncheck therelayisactivatedfor 3seconds waitingfor emergencybuttonsignal Ifmainunitdoes notreceive message a stuck...

Страница 19: ...officepriortotheinstallationoron siteafterinstallation The configurationsoftwareSafeLineProcanbe downloaded fromwww safeline group com Theconfigurationcable isprovided by SafeLine Remoteconfigurationw...

Страница 20: ...onpage6 Enterconfigurationcodesonthehandsetkeypad Remote configuration with telephone For remote configuration you can use any PSTN tone dial phone Dial the phone number of the SL6 Enter the function...

Страница 21: ...eentered Press unitnumber 1 9 1 Dialthephonenumberof theunit 2 Ifthereisonlyoneunit inthesystem proceedto step4 Iftherearemultiple unitsconnectedinparallel proceedtostep3 3 After2ringsthefirstSL6 unit...

Страница 22: ...sword 2shortbeeps enteringconfig mode 2shortbeeps Continue configure Quitconfiguration Invalidpassword onelongtone 2short beeps Invalidinput one longtone Lastcodehas tobe re entered Calldisconnectedor...

Страница 23: ...ne Dial toenter configurationmode 2short beeps enteringconfig mode Continueconfigure 2shortbeeps Invalidinput onelongtone Lastcodehas tobereentered Calldisconnected orend ofconfiguration SL6 willresta...

Страница 24: ...number 2ndphonenumber Calltype1stnumber Calltype2st number Alarmbutton delay Endconfiguration Example2 SLCC SafeLine CallCentre and3daytest Startconfiguration Enter P100IDcode Set test alarmtype Setnu...

Страница 25: ...aytime canbesetbyaddingasterisks between leadingnumberoftheswitchboardand telephonenumberforthealarmcallreceiver Eachasterisk isequaltooneseconddelay Example 1 11 0 1234567 Example 2 11 deletesthephon...

Страница 26: ...adeaftertheconfigurationis terminated Daysbetweentests 27 Numberofdaysbetweentestalarms 00 99 days Alwaystwodigits Max3daysaccordingtoEN81 28 00 Notestalarms Testalarmprotocol 31 0 P100 3 CPC 4 Caller...

Страница 27: ...ethecallpress To playtherecordedmessage pressthe desiredparameterfollowed by Forexample 61 inodertoplaythe messagefromthebusunit 0 Disablerecorded message 1 Enablesrecordedmessage Recordalarm messagef...

Страница 28: ...ult Ring tone timeout 72 Number of ring signals before dialling the next number default 08 External inputs Function 73 The first number selects the input i e Input 1 or Input 2 The second number selec...

Страница 29: ...ough the unit is programmed as automatic by pressing No ascending tones will be heard For repeating the Alarm messages to operator press 1 in all in out going calls 3 Swiss Mode Alarm operator mode On...

Страница 30: ...rlater thefollowingparametersare used 0 Alarmstatusoutputs default relay 1 1 Battery failure default relay 2 2 Pictogram Relay1 yellow relay2 green 3 ActivatewithDTMF8 9 relay1 DTMF8 relay2 DTMF9 4 Ma...

Страница 31: ...sanalarmeventafterconfigurationistermi nated 1 Emergencycall 2 Testalarm 3 Batteryfailure 4 Microphone speakerfailure 5 Receiptonvoicecall 6 Maintenance 7 Mainunit powerfailure 8 Stuckbuttonalarm GSM...

Страница 32: ...et Relay willbe activated whensettimereached Emergency callfailure Relay willbe activated whentheemergencycallfailedafter12 attempts EmergencyCallFail Systemfailure Relaywillbeactivated whenpower 230V...

Страница 33: ...lt Relayactivatesonceeveryday Ifsomethingiswrongwithbutton analarmissenttothe alarmreceiver IfDBcollective faultis programmedonanoutput thisis released Resets whenemergencybuttoninputischanged 3 Callr...

Страница 34: ...arunit Intercombetweenmachine roomandcar pit car top Mainstationtovoice station Press1 6onthe handset tocallrespectivevoicestation Voice stationtomainstation Pressthebuttononthe voicestationbrieflytoc...

Страница 35: ...utton again Alarmoperator madeconnection Calling1st phonenumber Calling2nd phonenumber Calling3rd phone number Calling4th phonenumber Wait1minute Linemissing orbusy Emergencyalarm activated Dialtone E...

Страница 36: ...k disabled PSTNinterface Flashing Red 400 400ms no line Slowly flashinggreen 200 4600ms lineOK Flashing green 400 400ms connectingcall Continuous green callconnected Fallback disabled GSMinterface Con...

Страница 37: ...larmdrop offfailsthroughtheprioritizedinterface theunitalsotriesthe secondaryinterface Ifdrop offfailsthrough any of theinterfaces e g noresponse busyline noP100starttone acknowledgement and Fallbacki...

Страница 38: ...eakerofthemainunitduringtheactive time Press the resetbuttontostopthesirensound Avoicemessagespecifically forFiremodeisplayed Refertothe Distressmessage sectionofthe ParameterList table When Firemodei...

Страница 39: ...rmed Thebatterytesttakesabout20minutes Ifthebatteryislow thetestwillbecancelled Whenusingtherelay LED 2andthebatteryalarmrelaywillbeactivated Relayscanbe activated forbatteryalarmbyusingparameter 88 p...

Страница 40: ...calltothecar press 1 Alternatively press 0 andwaitfordialtone thendialan externalcall Ifthesound transmissionisOK inbothdirections checkifyour emergencyoperatorsupportsthe chosenalarmtype Ifnoprotocol...

Страница 41: ...tle external interference Doamicrophonetest ThepictogramLEDsareflashing quicklyandsimultaneously The address switch is set to an invalid number 0 7 8 9 Valid numbers are 1 6 Theaddressswitchsetting ha...

Страница 42: ...oneof thesesolutions apply installaseparatecableforthetelephoneline Microphonecheck Call intotheSL6 and press thefollowingnumbersonthecaller s phone 1 Press 7 toactivate the car smicrophone 2 Press ac...

Страница 43: ...N 12015 2014 EMC Emission Electromagnetic compatibility EN 12016 2013 EMC Lifts Immunity Electromagnetic compatibility EN 62368 1 2014 AC 2015 LVD Information Technology Equipment EN 50581 2012 RoHS T...

Страница 44: ...0 60 03 sld safeline eu SafeLine Norway Solbr veien 49 1383 Asker Norway Tel 47 94 14 14 49 post safeline no SafeLine Denmark Erhvervsvej 19 2600 Glostrup Denmark Tel 45 44 91 32 72 info dk safeline s...

Отзывы: