14
SL6+ v.3.30 EN
Startup
LED 1
LED 2
LED 3
Reset
LED
1 2 3
GSM SIGNAL
STRENGTH
= 100 %
>= 85 %
>= 70 %
>= 55 %
>= 30 %*
>= 15 %
>= 0 %
*Minimum signal strength
for using GSM interface.
LED indication
front panel
Continuous green
Mains power supply OK
Flashing red (400/400 ms)
Battery operated, with power to the emergency light.
Continuous red
Battery operated, no power to the emergency light.
LED 1 indicates the power supply status
Light off
No active alarm/battery OK.
Rapidly flashing yellow
Active alarm not reset.
(200/200 ms)
Flashing red (400/400 ms)
Battery check in progress.
Continuous red
Battery test failure/no battery connected.
LED 2 indicates active alarm and battery condition
Flashing green (100/100 ms)
Fire mode activated.
Flashing green (400/400 ms)
Call connection in progress.
Slowly flashing green
Telephone line connected.
(200/4600 ms)
GSM network OK.
Continuous green
Call connected.
Flashing yellow (100/100 ms)
Incoming call.
Flashing red (400/400 ms)
PSTN: No telephone line connected.
GSM: Searching for GSM network.
Continuous red
No SIM card (when using GSM).
LED 3 indicates the phone line's status
Press for 3 sec
Show GSM signal strength (see table below).
Press 3 times
Start a self test (b bus initialization).
Press once
Resets an active alarm. Aborts calls in progress.
Press 5 sec - release
SL6+ turns off. NOTE! Refers to battery powered only!
Reset button