Your partner in lift safety
Antennvägen 10, 13548 Tyresö, Sweden
+46 (0)8-447 79 32, www.safeline-group.com
EU Declaration of Conformity
Product:
Lift telephone
Type / model:
SL6+
Article no:
*SL6, *SL6-4G, *SL6-GSM, *SL6-GSM-BOARD, *SL6-MAINBOARD, *SL6-MINI, *SL6-MINI-4G, *SL6-MINI-GSM, *SL6 A+,
*SL6 A+ MINI, *SL6 A+ 3G, *IF-BOARD-4G, *SL6-GSMR, *SL6-MINI-GSMR
Including voice stations:
*SLB3-COP, *SLB3-REC-PIC, *SLB3-REC-PIC-B, *SLB3-SM-PIC, *SLB3-SM-PIC-B, *SLB3-SM-PIC-L, *SLB-COP, *SLB-COP2,
*SLB-COP2-L, *SLB-COP-L, *SLB-COP-SEP, *SLB-IF1, *SLB-IF2, *SLB-RD,*SLB-RD-BUT, *SLB-REC, *SLB-REC-FIRE,
*SLB-REC-FIRE02, *SLB-REC-FIREK, *SLB-REC-FIREK02, *SLB-REC-LED, *SLB-REC-PIC, *SLB-REC-PIC-BUT *SLB-SM,
*SLB-SM-LED, *SLB-SM-PIC, *SLB-SM-PIC-BUT, *SLB-SM-PIC-LIGH, *SLB-SMD-PIC-BUT, *SLBR-COP, *SLBR-SM-PIC,
*SLBR-SM-PIC-B, *SLBR-REC-PIC, *SLBR-REC-PIC-B, , *SLBR-REC-PIC-B2, *SLBR-REC-PIC3, *SLBR-RD-B-L
Manufacturer:
SafeLine Sweden AB
Year:
2018
We herewith declare under our sole responsibility as manufacturer that the products referred to above complies with the
following EC Directives:
Directives
Radio Equipment (RED):
2014/53/EU
(Including EMC 2014/30/EU, LVD 2014/35/EU)
RoHS 2:
2011/65/EU
Lift
2014/33/EU
(Annex 4.5 & 4.9)
Standards applied
EN 81-20:2014
Lift: Safety & Technical requirements
EN 81-28:2003
Lift: Remote alarm on passenger and goods passenger lifts
EN 81-70:2003/A1:2004
Lift: Accessibility to lifts for persons including persons with disability
EN 81-72:2003
Lift: Firefighters lifts
EN 12015:2014
EMC: Emission, Electromagnetic compatibility
EN 12016:2013
EMC/Lifts: Immunity, Electromagnetic compatibility
EN 62368–1:2014/AC:2015
LVD: Information Technology Equipment
EN 50581:2012
RoHS: Technical doc. for assessment of restriction of RoHS.
For RED 2014/53/EU, an ” EU-Type Examination procedure” has been applied and is certified by notified body:
TÜV AUSTRIA SERVICES GMBH, Notified Body Nr: 0408
with the supporting assessments:
Standards applied
Article of Directive 2014/53/EU
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013
3.1 (a): Health and safety of the user
EN 62311:2008
EN 301 489-1 v2.1.1 + EN 301 489-52v1.1.0 Draft
3.1 (B): Electromagnetic Compatibility
EN 301 489-17 V3.1.1
EN 301 511 v12.5.1
3.2: Effective use of spectrum allocated
EN 301 908-1v11.1.1 /-2v11.1.1 /-13v11.1.1
EN 300 328 V2.1.1
Firmware used during assessment
Triorail TRM-5:
Rev. 03.016 / Rev. 03.017 / Rev. 03.019 / Rev. 03.025
GL865-Dual V3:
16.00.152 / 16.01.150 / 16.01.153
LE910-EU V2:
20.00.402
SafeLine SL6
4.45
Tyresö, 2017-04-07
Lars Gustafsson,
Technical Manager, R&D , SafeLine Group
Module
Notified body
Address
NB nr Test nr
TRM-5, CYW20732S
TÜV AUSTRIA SERVICES GMBH
Deutschstraße 10, 1230 Wien
0408
INE-AT/EMV18/138
N.A.
TÜV AUSTRIA SERVICES GMBH
Deutschstraße 10, 1230 Wien
0408
INe-AT/IT-18/109
TRM-5
Phoenix testlab GmbH
Königswinkel 10, D-32825 Blomberg, Germany
0700
13-113995
GL865-Dual V3
LE910-EU V2
Dekra Test &Cert
Dekra Test &Cert
Parque Tecnologico de Andalucia / SeveroOchoa 2,
29590 Spain
1909
1909
53051 RBN.001
52382 RCB.001
CYW20732S
NTS Silicon Valley
41039 Boyce Road, Fremont, CA 94538, US
0214.26
R 104750/51