29
SL6+ v.3.30 EN
Configuration
OTHER CODES
CODE DATA COMMENTS
Compatibility mode
*77*
- #
0 = Automatic voice switching
(default)
The call is validated when there is a voice response.
The call is terminated by pressing ”#”.
1 = Kone ECII (lift telephone)
When there is a voice response, some ascending
tones will be heard.
The call is validated by pressing ”4”.
The call is terminated by pressing ”0”.
The call is terminated without reciept notification by
pressing ”2”(the unit will call the next number).
2 = Manual voice switching
When there is a voice response, some ascending
tones will be heard.
The call is validated by pressing ”4”. Unit is still in
automatic mode. ‘
To enter manual mode and talk press ”*”.
To listen press ”7”.
Go back to automatic mode press ”4”.
The call is terminated by pressing ”#”.
It is possible to enter manual voice switching mode
although the unit is programmed as automatic by
pressing ”*”. No ascending tones will be heard.
For repeating the Alarm messages to operator, press
“1” in all in/out going calls.
3 = Swiss Mode (Alarm operator mode)
Only to be used in voice mode.
Disconnect by “0”.
Dials the next number if call timeout, blocking tone,
new dailing tone, and operator silence.
Indicator mode
*78*
- #
0 = Standard (default)
1 = Strictly EN81-28
Maximum communication
time. Incoming/outgoing calls
*79*
- #
1 - 5 minutes.
(Default: VOICE = 5 min, other protocols = 8 min)
Reset active alarm
*80*
- #
0 = Off
1 = On (default)
Auto answer
*81*
- - #
Number of signals before SafeLine answers incoming call.
Can be set from 00-16 (default = 02).
00 = Never answering.
Unit number
*82*
- #
Unit number [0] is set by default, and means that the
unit will respond immediately.
Unit number [1-9] is used when the units are sharing the
same phone line. When the unit number is assigned, the
specified unit is accessible for configuration.
Detect dial tone
*83*
- #
0 = Off
1 = On (default)
Set to off if SafeLine has problem to detect the dial tone.