Configuration
Alarm status outputs
• Relay will be activated when set time is reached.
• Relay will be deactivated when emergency
call ends.
Battery failure
• Relay will be activated when the battery test has failed.
• Relay will be deactivated by pressing the reset button.
Pictogram yellow (only relay 1)
• Relay will be activated when the alarm button is pressed (yellow
pictogram).
• Relay will be deactivated when the reset button is pressed or if
alarm centre presses “5”.
Pictogram green (only relay 2)
• Relay will be activated when the call is acknowledged (green
pictogram).
• Relay will be deactivated when the call is disconnected.
Activate with DTMF 8 (only relay 1)
• Relay will be activated for 5 seconds when DTMF “8” is pressed.
Activate with DTMF 9 (only relay 2)
• Relay will be activated for 5 seconds when DTMF “9” is pressed.
Manual reset
• Relay will be activated when set time reached.
Emergency call failure
• Relay will be activated when the emergency call failed after 12
attempts, ”Emergency Call Fail”.
System failure
• Relay will be activated when power (230 VAC) and PSTN/GSM net
is OK.
• Relay will be deactivated when power supply is gone more then
15 min or when there is no GSM-net.
Emergency bell
• Relay will be activated when the emergency bell input is active.
• Relay will be deactivated when the emergency bell input is
deactivated.
Relay functions
This applies for SW 4.00 or later.
(For functions of earlier versions,
please contact the Support team.)
Relays 1 and 2 can be
programmed independently.
Call retry failure
•
Relay is activated when current relay is in Standby Mode.
•
Relay is deactivated if failing to deliver an alarm. If Fallback is
active, both interfaces have failed. Relay closes at successful
deliverance.
Automatic
emergency button check
•
Relay is active once every day, checking emergency button.
•
Relay is deactivated when emergency button input is changed,
or if DB collective fault is programmed on an output.