English
27
FAULT
Fault 51
Timing of motor
microswitch switching not
correct.
Fault 52
Excessive current
absorption by one motor.
Fault 53
Motor working even when
not controlled.
Fault 54
Power cut occurred during
product dispensing cycle.
Fault 55
Motor presence not
detected.
CURE
Inspect the motor and
remove the cause of the
problem, reset and re-
inspect the motors. If the
problem still persists,
contact our Authorized
Customer Service center.
Remove the cause of the
problem, reset and re-
inspect the motors. If the
problem still persists,
contact our Authorized
Customer Service center.
Replace the motor, reset
and check the motors.
Reset and check the
motors.
Check the wiring
connections and remove
the causes of the problem.
Reset and check the
motors.
Important
After every trouble reset, the motors which had caused the
problem should be re-inspected.
7.5.6 Motor check
Each individual motor, or all the motors in a sequence,
can be checked from this menu.
During individual motor checking, the motor status is
displayed in the second line of the display.
7.5.2 Partial counters
The following information is displayed in this menu:
- total number of selections dispensed by the vending
machine;
- partial number of dispensed selections;
- standard selections;
- free selections.
7.5.3 Data reset
Access to the DATA RESET item can only be obtained if
YES had been set in the RESET VALIDATION item of the
SYSTEM MANAGEMENT menu (programming menus).
If NO had been set in that item, the DATA RESET item will
not be displayed.
By pressing the key
, you will reset the data displayed
in the PARTIAL COUNTERS menu.
If a TIME KEEPER feature is available, by pressing the key
, the data displayed in the STATISTICS menu will also
be reset.
7.5.4 History counters
This menu displays the number of total and partial selections
dispensed by the vending machine. In this case, data reset
will not be possible.
7.5.5 Motor faults
This menu displays the diagnostics of the connected motors
and indicates the relevant motor status. The following
messages can be read on the machine display:
- FAULT 53 (53 = fault code)
- OK
- NOT AVAILABLE
The types of fault and their corresponding identification
codes (see chart below) are also indicated.