31 - English
Safety
Sensor
Fig. 52
Fig. 53
NOTE:
The top of the sensor should be between four and
six inches above the floor.
NOTE:
The receiving sensor has a green LED. Ensure that
the lens on this sensor is not exposed to direct sunlight.
Mark the position of the hole in the bracket.
Secure brackets in place using nails or drill 3/16 in. pilot
holes and secure with lag screws. Tighten screws with
an 7/16 in. socket.
NOTE:
Use lag screws and concrete anchors (not
included) when installing the brackets into concrete, brick,
or other masonry.
WARNING:
To avoid the risk of death, electric shock, or serious
personal injury ensure that the garage door opener is
unplugged and the battery pack is removed before wiring
the sensors.
Safety
Sensor
Lag
Screw
Fig. 54
WARNING:
Connect the sensors using low voltage wires provided
only to prevent the risk of electric shock or serious
personal injury.
Route the wires from the sensors to the safety sensor wire
terminals. Attach the wires to the wall and ceiling using
the insulated staples. Secure the staples to the wall and
ceiling using a hammer.
Using wire strippers, strip 1/2 in. of insulation from the
ends of each wire.
To install wires into a wire terminal, depress the tab above
the terminal, insert the wires, and release the tab.
Twist the gray striped wires from both sensors together
and insert them into the right safety sensor terminal
marked with G.
Safety Sensor
Wires
Insulated
Staples
Power
Head
LED
(Green)
LED
(Red)
Safety Sensor
(Transmitter)
Safety Sensor
(Receiver)
Arrow
INSTALLATION
Fig. 55