INSTALLING THE INDOOR KEYPAD
See Figure 57.
Install the indoor keypad according to the instructions
included in the keypad operator’s manual.
Locate the Entrapment Label.
WARNING:
Do not use garage door opener if keypads or remotes
do not start and stop the motor. An opener that cannot
be controlled with a keypad or remote is dangerous,
can result in death or serious personal injury, and must
be repaired.
WARNING:
Make sure the keypad is mounted high enough to prevent
unauthorized activation of the garage door opener. It
should be placed at least five feet above the floor so that
it is inaccessible to children. Unauthorized activation of
the opener can result in death or serious personal injury.
WARNING:
Do not start or stop the garage door opener if there is a
person or object in the path of the door, the door has not
been properly balanced, or if you cannot see the doorway.
Failure to follow these instructions can result in death or
serious personal injury.
WARNING:
Entrapment warning label contains important safety
information. Install entrapment warning label next to the
indoor keypad in a prominent location. Use insulated
staples or other mechanical means if the label will not
adhere to the wall.
For details about using the indoor keypad, see
Using the
Indoor Keypad
in the
Operations
section.
Twist the white wires from both sensors together and
insert them into the left terminal marked with W.
For alignment instructions, see
Aligning The Safety
Sensors
later in this section.
INSTALLATION
Fig. 57
Child can become trappe
d or pinned under an auto
matic garage door resulti
ng
in serious injury or death
.
• Do not allow children to
walk or run under a clos
ing door.
• Do not allow children to
operate door opener con
trols.
• Always keep a closing d
oor within sight.
• In the event a person is
trapped under the door, p
ush the control button or
use the emergency rele
ase.
• This operator system is
equipped with an unatte
nded operation feature. T
he
door could move unexp
ectedly. Not intended for
use with single panel ga
rage
doors.
Test door opener monthly
:
• Refer to Operator’s M
anual.
• Use a 1 ½ inch thick ob
ject (or 2 X 4 laid flat) pla
ced on the floor under the
closing door.
• In the event the door d
oes reverse upon contact,
adjust, repair, or replace
the
opener.
Do not remove or paint over this label.
Mount this label next to the wall control.
Mount the wall control out of the reach of children at least 5 feet above the floor
.
Entrapment
Label
Wires
(White)
Wires
(Striped)
Fig. 56
“W”
“G”
Tab
Wire Terminal
(Safety Sensor)