7 – Commissioning
RWO GmbH
●
Marine Water Technology
●
Bremen
●
Germany
Issue 2014-04-10
Note
According to IMO MEPC 107 (49), the outboards
pipeline must be equipped with a 3-way valve
(pos. 55) and non-return fittings (pos. 24). Please
observe also the corresponding material
specifications of the respective classification board
for fittings on the ship's side. For operation of the
SKIT S-DEB, no special fittings in the outboards line
are required, but the outboards outlet should be
above the upper edge of the oil separator.
Recirculation outlets
The pipeline from the recirculation outlet at the 3-way
valve (pos. 23 chapter
à
3.14.3) and at the manual 3-way
valve (pos. 55 chapter
à
3.14.3) back to the bilge or the
bilge water tank must be laid without pressure and be
equipped with a venting pipe.
7.7
Pipelines
For connecting the SKIT S-DEB oil separator system we
recommend the following pipeline cross-sections, chapter
à
3.14.3