9 – Process description
RWO GmbH
●
Marine Water Technology
●
Bremen
●
Germany
Issue 2014-04-10
monitor OMD. No voltage is applied to the solenoid valve
of the 3-way valve (pos. 23). The 3-way valve (pos. 23)
guides the water back to the bilge or the bilge water tank.
The display of the oil separator control system still
indicates
and the oil separator keeps operating.
Additionally an alarm message to the engine control room
is activated. On the monitor, two red LEDs signal that both
limit values are exceeded and thus an alarm.
Process overview of the situational and valve states
Monitor OMD Pos
.
Designati
on
Valve
state
Solenoid valve
state
Oil content
less than
14ppm (4ppm)
(limit value 1,
by factory
default) at the
sample point
downstream of
the OWS,
upstream of
adsorber
57
3-way
valve in
sample
line
Measurin
g
upstream
of
adsorber
Voltage
23
3-way
valve
recirculati
on
Outboard
s
Voltage
58
3-way
valve
bypass
Bypassin
g
adsorber
Voltage
Oil content is
14ppm (4ppm)
but less than
15ppm (5ppm)
(limit value 1 /
2 by factory
default) at the
sample point
downstream of
the adsorber
57
3-way
valve in
sample
line
Measurin
g
downstre
am of
adsorber
No voltage
23
3-way
valve
recirculati
on
Outboard
s
Voltage
58
3-way
valve
bypass
Passing
adsorber
No voltage
During
situation mode
b), the system
periodically
checks the oil
content at the
sample point
upstream of
the adsorber
every 5
57
3-way
valve in
sample
line
Measurin
g
upstream
of
adsorber
Voltage
23
3-way
valve
recirculati
on
Back to
bilge /
bilge
water
tank
No voltage
BETRIEB AUTO
ENTOELT MIT
ADSORBER