10 – Operation
RWO GmbH
●
Marine Water Technology
●
Bremen
●
Germany
Issue 2014-04-10
LANGZEIT ALARM MIN.
AENDERN? NEIN JA
LONG TIME ALARM
MIN.
MODIFY? NO YES
The set value results from the maximum bilge water
volume on board; it can be calculated by this formula:
Minutes = maximum bilge water volume in m3 divided by
pump output in m3/h * 60 plus 15 %. If the oil separator
has not processed the bilge water within that time, the
LONG TIME ALARM
is triggered.
Search for the cause, e.g. a leak in the suction line. The oil
separator would then permanently suck air.
These displays to select changes, set values and save
values are available for every user setting.
The only exception is the section "Restore defaults".
WERKSEINSTELL. HOLEN.
AENDERN? NEIN JA
RESTORE DEFAULTS.
MODIFY? NO YES
If you reply the item "Get factory settings" with "YES",
there is not sub-menu to adjust the values, but all
parameters (except flushing time) are set to the general
initialisation settings.
Note
If you had set values (e. g. for LONG TIME ALARM)
individually, these must be set again to the
previously set values after selecting "Restore
defaults".
In general:
If user settings have been changed or factory
settings have been retrieved, you must restart the
control software to accept the changes by switching
the system off and on again.