Installation
D-73d Series Installation/Operation Manual
41
Additional
Connections to the
Dimension Digital
Controller (Optional)
The Dimension Digital Controller provides the following interfaces to external
equipment that allow it to control or be controlled by that equipment:
• An RS-232 interface to a PC or control/automation system;
• Three (3), 12-volt trigger outputs;
• An infrared (IR) repeater input;
• An Ethernet network interface for firmware updates and maintenance notifications.
The following sections describe how to make these interface connections.
RS-232 Controller Connection:
Use a straight-through, 9-pin RS-232 cable to
connect a PC or control/automation system (if present) to the RS-232 port on the
Dimension Digital Controller; see Figure 3-16.
Figure 3-16. RS-232 Control System Connection to Dimension Digital Controller
PC / Control
RS-232
IR
Pri. Display Control
Sec. Display Control
HDMI 5
HDMI 6
HDMI 7
HDMI 8
Ethernet
HDMI Out
To Sec. Display
HDMI Out
To Pri. Display
HDMI Out
Audio Only
IR
Pri. Display Control
Sec. Display Control
HDMI 5
HDMI 6
HDMI 7
HDMI 8
Ethernet
HDMI Out
To Sec. Display
HDMI Out
To Pri. Display
HDMI Out
Audio Only
1
2
3
4
5
7
8
9
6
to Automation/
Control System
or PC
2 Receive Data
(to ctrl. system)
3 Transmit Data
(from ctrl. system)
5 Ground
(none of the other pins are used)
Содержание D-73d Ultra
Страница 2: ......
Страница 14: ...Table of Contents xiv D 73d Series Installation Operation Manual...
Страница 22: ...Introduction 6 D 73d Series Installation Operation Manual Notes...
Страница 36: ...System Overview 20 D 73d Series Installation Operation Manual Notes...
Страница 114: ...Operation 98 D 73d Series Installation Operation Manual Notes...
Страница 150: ...Specifications 134 D 73d Series Installation Operation Manual Notes...
Страница 151: ......
Страница 152: ...Runco International 800 23RUNCO Fax 503 748 8161 www runco com 020 1082 02 Rev A March 2014...