Installation
52
D-73d Series Installation/Operation Manual
Dimension Digital Controller
1.
Select
Calibration -> Adjustment Mode
and set it to
Secondary
.
2.
Select
Service -> Test Video
and choose
Secondary Alignment
.
Projector (Align Secondary/Right
Image with Screen)
1.
Align the image to the screen by
adjusting the Right (bottom) primary
lens zoom, focus and H/V offset.
2.
Tighten the Right primary lens lock
screw.
3.
D-73d/CineWide with AutoScope
only: Remove anamorphic lenses.
Set the AutoScope transport motor
AC switch to the “on” position.
Note:
The default warp is 46 pixels on
the left and right sides (x) and 26 pixels
at the top and bottom (y). If more is
needed, use the “Image Alignment”
controls to increase it.
Dimension Digital Controller
1.
For a ceiling-mounted (inverted) and/or
rear-projection installation, select
Service -> Display Device ->
Configure -> Installation ->
Picture Orientation
and set it as needed.
2.
Select
Aspect Ratio
and set it to
Cinema
.
On a D-73d/CineWide with AutoScope,
this should position the anamorphic lens
transport in front of the primary lenses.
3.
Select
Calibration -> Adjustment Mode
and set it to
Primary
.
4.
Select
Service -> Test Video
and choose
Primary Alignment
.
Projector
1.
(Re-)install anamorphic lenses.
2.
Align the primary (left-eye) image
with the screen by adjusting the Left
(top) anamorphic lens to produce the
least amount of distortion.
Dimension Digital Controller
1.
Select
Calibration -> Adjustment Mode
and set it to
Secondary
.
2.
Select
Service -> Test Video
and choose
Secondary Alignment
.
Projector
1.
Align the secondary (right-eye)
image to the screen by adjusting the
Right (bottom) anamorphic lens to
produce the least amount of
distortion.
Dimension Digital Controller (Align
Secondary Image with Primary Image)
1.
Select
Aspect Ratio
and set it to
16:9
.
2.
Select
Calibration -> Adjustment Mode
and set it to
Secondary
.
3.
Select
Calibration -> Image Alignment ->
Corner Alignment
, check the
Primary
Test Pattern
and
Secondary Test Pattern
boxes and adjust corners.
4.
Select
Calibration -> Image Alignment ->
Midpoint Alignment
, check the
Primary
Test Pattern
and
Secondary Test Pattern
boxes and adjust midpoints.
Projector
No adjustment needed.
Note:
The Primary lens image is
usually left un-warped. This provides
the best image quality and will be
un-scaled for 1080p sources. You can
adjust the Primary image if needed,
however, by setting the
Adjustment
Mode
to
Primary
, checking the
Primary Test Pattern
and
Secondary
Test Pattern
boxes and adjusting the
corners and/or midpoints prior to this
step.
Table 3-6. D-73d Optical Alignment Procedure (with Anamorphic Lenses) (continued)
Содержание D-73d Ultra
Страница 2: ......
Страница 14: ...Table of Contents xiv D 73d Series Installation Operation Manual...
Страница 22: ...Introduction 6 D 73d Series Installation Operation Manual Notes...
Страница 36: ...System Overview 20 D 73d Series Installation Operation Manual Notes...
Страница 114: ...Operation 98 D 73d Series Installation Operation Manual Notes...
Страница 150: ...Specifications 134 D 73d Series Installation Operation Manual Notes...
Страница 151: ......
Страница 152: ...Runco International 800 23RUNCO Fax 503 748 8161 www runco com 020 1082 02 Rev A March 2014...