External Control
D-73d Series Installation/Operation Manual
105
Command and Response
Examples
Here are some examples of serial commands and their responses:
Serial Command List
Table 6-1 lists all supported commands.
Command
Command Data
Response
Power query when
unit is powered on
(PWR?) [CR]
(0;PWR=1) [CR]
Set power to 0 (off)
(PWR=0) [CR]
(0;PWR=0) [CR]
Increment bright-
ness from 24 to 25
(BRT+) [CR]
(0;BRT=25) [CR]
Invalid command
(ZZZ=0) [CR]
(1;ZZZ=0) [CR]
Invalid parameter
(received string,
expected integer)
(CON=”Some string”)
[CR]
(9;CON=”Some string”)
[CR]
Table 6-1. Serial Commands
Setting
Command
Code
Read/
Write
Inc/
Dec
Min
Value
Max
Value
String?
Notes
Advanced Color Temp Auto Color
Enable
AAC
R/W
No
0
1
No
0 = Off; 1 = On
Advanced Color Temp Diagnostic
Color
AAD
R/W
No
0
6
No
0 = White
1 = Red
2 = Green
3 = Blue
4 = Yellow
5 = Cyan
6 = Magenta
Adjustment Mode
ADJ
R/W
No
0
2
No
0 = Both
1 = Left
2 = Right
Apply Image Alignment Values
AIA
R/W
No
0
1
No
0 = Off; 1 = On
Altitude
ALT
R/W
No
0
1
No
0 = Auto
1 = High
Auto Power Off Enable
APE
R/W
No
0
2
No
0 = Off; 1 = On; 2 = No Signal
Auto Power Off Timer
APT
R/W
Yes
1
24
No
Auto Perform Upgrade
APU
R/W
No
0
1
No
0 = Off; 1 = On
Aspect Ratio Copy
ARC
W
No
N/A
N/A
No
Action will be performed on any
setting value
Aspect Ratio Paste
ARP
W
No
N/A
N/A
No
Содержание D-73d Ultra
Страница 2: ......
Страница 14: ...Table of Contents xiv D 73d Series Installation Operation Manual...
Страница 22: ...Introduction 6 D 73d Series Installation Operation Manual Notes...
Страница 36: ...System Overview 20 D 73d Series Installation Operation Manual Notes...
Страница 114: ...Operation 98 D 73d Series Installation Operation Manual Notes...
Страница 150: ...Specifications 134 D 73d Series Installation Operation Manual Notes...
Страница 151: ......
Страница 152: ...Runco International 800 23RUNCO Fax 503 748 8161 www runco com 020 1082 02 Rev A March 2014...