background image

BARCO PROJECTION SYSTEMS

Date :
100298

Art. No. :

R5976002

R9002041
R9002048

INSTALLATION MANUAL

RETROGRAPHICS

808s

Revision :
00

Содержание R9002041

Страница 1: ...BARCO PROJECTION SYSTEMS Date 100298 Art No R5976002 R9002041 R9002048 INSTALLATION MANUAL RETROGRAPHICS 808s Revision 00...

Страница 2: ...y BARCO NV February 1999 All rights reserved Trademarks are the rights of their respective owners Printed in Belgium BARCO n v Projection Systems Noordlaan 5 B 8520 Kuurne Belgium Tel 32 56 368211 Fax...

Страница 3: ...s voltage adaptation 5 2 Switching on the projector 5 4 Source Connection 6 1 Signal input connection on the projector 6 1 Connecting a composite video source to port 1 6 1 Connecting a S Video or Vid...

Страница 4: ...eplace your obsolete outlet Do not defeat the purpose of the grounding type plug WARNING FOR THE CUSTOMERS THIS APPARATUS MUST BE GROUNDED EARTHED via the supplied 3 conductor AC power cable If the su...

Страница 5: ...i reflective coating therefore avoid touching the lens To remove dust on the lens use a soft dry cloth Do not use a damp cloth detergent solution or thinner On repacking Save the original shipping car...

Страница 6: ...and place them on floor Save the original shipping cartons and packing material they will come in handy if you ever have to ship your retroprojector For maximum protection repack your projector as it...

Страница 7: ...Unpacking and dimensions 2 2 5976002 RETROGRAPHICS 808s 100299 Projector dimensions in mm...

Страница 8: ...r to avoid any damage of the screen surface Lift up the mirror cabinet and place it on the projector cabinet Both centering pins on the the mirror cabinet must match the centering holes in the project...

Страница 9: ...n the screws a little and slide the profile over the screws Fixate the 3 screws Unfolding the mirror house To unfold the mirror house handle as follow 1Unlock the mirror cabinet by pushing the bracket...

Страница 10: ...ion set up 3 3 5976002RETROGRAPHICS808s100299 Closing the mirror house Toclosethemirrorhousing unlockthepinlockonbothsidesandpush the mirror house to the front until it clicks into the transportation...

Страница 11: ...r of the controller module by loosening both retaining screws of the metal protection plate Pivot this plate downside image 2 1 2 The DIP switches are located on the back side of this metal protection...

Страница 12: ...tting the projector address The projector s address may be set to any value between 0 and 255 When the address is set the projector can be controlled now by RCU for addresses between 0 and 9 IBM PC or...

Страница 13: ...ssary to enter an address even when the displayed address is correct Use the numeric keys to enter the address 1 2 3 4 5 6 7 8 0 1 OFF ON 1 2 3 4 5 6 7 8 ON OFF Power up mode OFF ON Power up mode The...

Страница 14: ...needed to enter the adjustment mode Position of DIP Switch No 5 ON password mode enabled OFF password mode disabled baud rate code speed 0 110 1 150 2 300 3 600 4 1200 5 2400 6 4800 7 9600 More infor...

Страница 15: ...ug proceed as follows The yellow green wire is ground and must be connected to the terminal in the plug which is marked by the letter E or by the safety earth symbol or colored yellow and green The bl...

Страница 16: ...mains power input of 230 Vac The RETROGRAPHICS 808s R9002048 leaves the factory to operate on a mains power input of 120 Vac Adaptation of the power input of the projector between 230 Vac and 120Vac o...

Страница 17: ...2 is reached The fixation points will automatically jump into the correct position when turning the frame to this position Openthecoverplateoftheelectronics frontsideoftheretroprojector by loosening...

Страница 18: ...ard to switch the projector ON and OFF if the switch is pressed ON if the switch is Not pressed OFF The projector can be started up in the operational mode image displayed or in the stand by mode depe...

Страница 19: ...the warm up period every 30 seconds a text box with the remaining time will be displayed on the screen for 2 seconds This text box will be displayed every time on another place If a key other than th...

Страница 20: ...ld in RCU press digit button 1 Note if using the loop through Video output then set the Termination Switch to the OFF position Composite video signals from a VCR OFF air signal decoder etc 56 1 56 287...

Страница 21: ...DOUBLER ON Highlight Picture Tuning and press ENTER Select Selected source and press ENTER Input selection with the RCU or the local keyboard press digit button 2 Depending on the priority setting in...

Страница 22: ...Termination Resistors and Switches When changing a switch position or removing a resistor turn off the projector and unplug the power cord from the wall outlet 75 W Termination resistors In case of c...

Страница 23: ...detection with the RCU or the build in RCU press digit button 4 or 5 Connecting a RGB Analog source with Tri level 56 1 56 2875 5 02 7 5 5 PORT 4 5 PORT3 COMM PORT PORT1 PROJECTORMODE POWER MAINS inv...

Страница 24: ...a Component Video source with Tri 56 1 56 2875 5 027 5 5 PORT 4 5 PORT3 COMM PORT PORT1 PROJECTORMODE POW ER MAINS with the RCU or the build in RCU press digit button 8 Connecting external loudspeake...

Страница 25: ...stereo sound will be lost Speaker selection switch To switch between internal loudspeakers or external loudspeakers When pressed set for operation with sound output from the built in speaker system Wh...

Страница 26: ...ORBITING CONTR MODULATION SOFT EDGE Orbiting Mode Toggle Switches The orbiting module is provided with a three pin connector for connection with the BARCO s BCl link option module used in multiple pro...

Страница 27: ...biting mode set to OFF This alignment must be performed in case of a multiple projector installation with Master and Slave projectors in order to ensure a correct operation of the Orbiting for all pro...

Страница 28: ...ss ENTER When adjusting the horizontal and the vertical deviation the picture moves in corresponding direction allowing the set up of the deviation without orbiting operation EXIT to return SLAVE ORBI...

Страница 29: ...g the G2 adjustment menu these green LEDs must be out If not follow the next procedure to adjust the G2 open the metal cover on the lens side covering the modules by turning out the retaining screws o...

Страница 30: ...factory preset To carry out the Blue Gamma Correction Push the control disc forward or backward to highlight the item BLUE GAMMA CORRECTION in the menu and then press ENTER If EXIT is pressed the proj...

Страница 31: ...adjust the Blue Midlights a text box with a bar scale 0 16 will be displayed to visualise the magnitude of the correction Press ENTER to return to the Gamma Corrections menu GAMMA CORRECTIONS BLUE GA...

Страница 32: ...AL FIRE PROTECTION ASSOCIATION STD 704M SIGNAL TRESHOLD LIMIT VALUE Units TRESHOLD LIMIT VALUE Units BASE METAL ALLOYS METALLIC COATINGS FILLER METAL PLUS COATING OR CORE FLUX OTHERS MATERIAL SAFETY D...

Страница 33: ...ATA OR THE RESULTS TO BE OBTAINED FROM THE USE THEREOF VENDORASSUMESNORESPONSABILITYFORINJURYTOVENDEEORTHIRDPERSONSPROXI MATELY CAUSED BY THE MATERIAL IF REASONABLE SAFETY PROCEDURES ARE NOT AD HERED...

Отзывы: