Section 2 - Rumble Hog Systems
Blower airflow is expelled through a silencer con
-
nected to the outlet side of the blower. A flapper
installed on the silencer keeps water and debris
from entering the system damaging the blower
when the unit is shutdown.
Blower components have extremely small toler-
ances and must be protected from the debris. If
debris ever gets into the blower impellers, use
paint/lacquer thinner or another non-corrosive
cleaner to remove any residue build up inside. It
will be necessary to disconnect the hose to the
silencer in order to clean the blower. If any debris
gets into the blower, it can cause severe damage
to the blower.
CAUTION
THE BLOWER’S INTERNAL COMPONENTS HAVE EXTREMELY
SMALL TOLERANCES AND MUST BE PROTECTED FROM THE
DEBRIS AND CORROSION. ANY FOD (FOREIGN OBJECTS
OR DEBRIS) INCLUDING EXCESSIVE WATER, CAN CAUSE
SEVERE DAMAGE TO THE BLOWER.
The blower must be shutdown properly and in-
ternal components protected from corrosion with
a light protective oil such as WD-40, LPS or CRC
when the system is shutdown for the evening or
an extended period. This is accomplished by open-
ing the access door and removing the plug in the
filter element while the blower operating. Allow
Filter & Oil Injection Port
Blower & Hydraulic Motor
Blower Drive End & Grease Fitting Locations
the blower to operate for several minutes to dry
out blower components, then spray oil into the
port for 20-30 seconds. Refer to the Operation
and Lubrication & Maintenance sections for addi-
tional information on maintaining and protecting
the blower.
Содержание RH7500
Страница 1: ...RH7500 Operations Manual ...
Страница 2: ......
Страница 6: ...6 NOTES ...
Страница 10: ...10 NOTES ...
Страница 19: ...19 Section 1 Safety Information ...
Страница 20: ...20 NOTES ...
Страница 108: ...108 NOTES ...
Страница 150: ...150 NOTES ...
Страница 155: ...155 Appendix 3 Tools Spare Parts ...
Страница 156: ...156 Appendix 3 Tools Spare Parts ...
Страница 158: ...158 NOTES ...
Страница 163: ......