Ruckus ICX 7850 Switch Hardware Installation Guide
Part Number: 53-1005580-01
Mounting the Device
Four-Post Rack Mount Installation (ICX-RMK-4POST-TL)
1.
Position the device in the rack, as shown in
, providing temporary support under the device until the rail kit is secured to
the rack.
2.
Attach the right front bracket to the right front rack post using two 10-32 x 5/8-in. panhead screws and two retainer nuts. Use
the upper and lower holes in the bracket.
3.
Attach the left front bracket to the left front rack post using two 10-32 x 5/8-in. panhead screws and two retainer nuts. Use the
upper and lower holes in the bracket.
4.
Tighten all the 10-32 x 5/8-in. screws to a torque of 25 in-lb (29 cm-kg).
FIGURE 10
Positioning the Device in the Rack
Four-Post Rack Mount Installation (ICX-RMK-4POST-TL)
Use the following instructions to install the Ruckus ICX 7850 switch in EIA racks that are between 46 cm and 79 cm (18 in. to 31 in.)
using the four-post flush-mount rack kit included with the switch.
NOTE
Hardware devices illustrated in these procedures are only for reference and may not depict the device you are installing into the
rack.
Time and Items Required
Allow 15 to 30 minutes to complete the installation.
The following items are required to install the device using the four-post flush-mount rack kit (ICX-RMK-4POST-TL):
•
#2 Phillips torque screwdriver
•
1/4-inch slotted-blade screwdriver
1
Screws, 10-32 x 5/8-in., panhead Phillips
2
Retainer nuts, 10-32