Ruckus ICX 7850 Switch Hardware Installation Guide
57
Part Number: 53-1005580-01
Monitoring the Device
Diagnostic Tests and Monitoring
Diagnostic Tests and Monitoring
Ruckus FastIron software includes diagnostic tests to help you troubleshoot the hardware. System diagnostic software is designed to
fulfill the purpose of offline diagnostics. In offline diagnostics, you must turn the diagnostic flags on or off to execute diagnostic tests
during the next bootup.
The CLI commands for system diagnostic tests are
dm diag
and
dm alt-diag
. These diagnostic tests verify all available hardware
components including:
•
I2C devices
•
EEPROM
•
CPU packet
•
Line rate
During system diagnostic testing, the system is completely under the control of the diagnostic software. All hardware components are
verified, and results are displayed on the console. In cases where a failure is detected, results and corrective actions will be displayed. After
the system diagnostic testing is complete, the system exits from the diagnostic mode and reloads the system for normal operation.
System diagnostic testing runs at link speeds of 1 Gbps, 10 Gbps, 25 Gbps, 40 Gbps, or 100 Gbps depending on the speed of the link
being tested and the type of port.
The Ruckus device is engineered for reliability and requires no routine operational steps or maintenance. You can monitor the device by
paying attention to the following information:
•
The LEDs showing the status of system components
•
A description of the operations that the device performs when you power it on
The following commands can be especially helpful in monitoring the health status of various device components. For details about these
commands, refer to the
Ruckus FastIron Management Configuration Guide
.
•
show chassis
•
show system