Universal Controller (CVS-012)

The Universal Controller (CVS-012) is a device used for controlling hazard warning lighting
equipment that incorporates a built-in siren and a number of other power management
devices,  such  as  a  run  lock  and  split  charger  switching  logic.  The  Universal
Controller (CVS-012) is also available without a built-in siren (UNI-CON-005).

The unit has been primarily designed to control a lightbar, which is
achieved via a variety of compatible switching devices including
handsets and simple toggle switches. Each switch can be programmed
via the built-in programming interface, or, for the more specialised and
technically minded operator, we can supply PC software, but if this
option is used a hardware dongle is required to link between the Universal
Controller (CVS-012) and a PC, which acts as a program storage and software
loading device.

As well as the above features the unit has special signal inputs to connect directly to vehicle inputs, on board status LEDs for all the
main outputs, monitor outputs that reflect the switching status of the device (ideal for connecting to a data recorder), and finally a CAN
bus interface. The CAN bus is pre-programmed for connection to common vehicle protocol, such as the Ford Focus, but can be 
programmed to suit a particular vehicle.

Product Versions

Both versions of the Universal Controller (CVS-012) are generally available in three formats as shown below. The final choice is dependant
upon the level of complexity the installation requires and how much programming the operator wishes to do. As such the Universal
Controller can be supplied to any of the following formats:

Standard Factory Set-Up:

The unit is pre-set at RSG with the ‘Standard Factory Set-Up’ software which will operate with most 

industry standard lightbars and vehicle lighting, therefore the unit will require little or no adjustment on installation. Further 
sections of this manual show typical application drawings for this configuration.

Custom Factory Set-Up:

The unit is pre-set at RSG to operate in-line with customers specific installation and operational 

requirements. Before the unit is purchased we recommend some technical discussion in order to specify how the unit needs to 
be configured. The device will then be allocated a unique part number, allowing a set-up record to be stored and so guaranteeing 
the supply of future products to the same specification. Further sections of this manual show typical application drawings for this 
configuration.

Customer Programmable Unit: 

The unit would initially be supplied with a dongle (sold separately) and a CD containing 

‘Standard Factory Set-Up’ software, ‘Full Programming Software’ and the ‘Software Manual’. Allowing the customer to directly 
program the unit to meet specific requirements. Once the programming is completed RSG would either supply further units
pre-programmed to the ‘Customers Specification’ or with the ‘Standard Factory Set Up’ allowing the customer to define their 
specific software. In cases where the units are supplied direct from RSG and pre-loaded with customer specified software the
device will be allocated a unique part number to ensure continuity of supply. Although further sections of this manual show
typical application drawings for this configuration, a copy of the ‘Full Programming Software and Manual’ would be required 
to appreciate the overall operation of the device.

RSG Engineering Limited

Telephone :

01543 438800  

Fax :

01543 438801  

Email :

[email protected]  

Web :

www.rsg-ontop.com

1:

2

UNIVERSAL CONTROLLER (CVS-012) USER GUIDE

V2

B

: GENERAL OVERVIEW

:

General Overview

Universal Controller

(CVS-012)

Содержание CVS-012

Страница 1: ... Outputs 7 3 5 Monitor Outputs 7 3 6 RS485 Serial Interface 8 3 7 CAN Bus Serial Interface 8 3 8 AND Logic 8 4 User Interface 12 4 1 Display Contrast Settings 8 4 2 Status Screens 9 5 Setup Menu 12 5 1 Menu Organisation 12 5 2 General Options 13 5 3 Factory Defaults 14 5 4 Output Channels Options 14 5 5 Save Settings 16 6 Wiring and Connections 17 6 1 Power Supply Connections 17 6 2 Bank A and Ban...

Страница 2: ...1 10 J1 Universal Multi Way Handsets Overview 1 11 J2 Universal Multi Way Handsets Specification 1 12 J3 Universal Multi Way Handsets Specification 1 13 J4 Universal Multi Way Handsets Programming 1 14 J5 Universal Handset Plus Programming 1 15 K1 Interaction of Handset 1 16 K2 Typical Application Drawings HLF 1 17 K3 Typical Application Drawings Siren 1 20 K4 Typical Application Drawings Run Lock...

Страница 3: ...ing Limited Telephone 01543 438800 Fax 01543 438801 Email sales rsg ontop com Web www rsg ontop com 1 1 The following parts are for standard units pre loaded with Standard Factory Set up software The following parts are current compatible switching options for controlling hazard warning equipment via the Universal Controller CVS 012 Universal Handset HSPT01 12 Description Universal handset with bu...

Страница 4: ...Factory Set Up software which will operate with most industry standard lightbars and vehicle lighting therefore the unit will require little or no adjustment on installation Further sections of this manual show typical application drawings for this configuration Custom Factory Set Up The unit is pre set at RSG to operate in line with customers specific installation and operational requirements Bef...

Страница 5: ...own above and is no longer available to order That said there are a number that are still in circulation if you require further information please do not hesitate to contact our dedicated sales team Alternative PWM Handsets The Standard Factory Set up software with the Universal Controller CVS 012 allows compatibility with certain alternative PWM handsets As there are many types of handsets keypad...

Страница 6: ... Email sales rsg ontop com Web www rsg ontop com 1 4 UNIVERSAL CONTROLLER CVS 012 USER GUIDE V2 D TYPICAL SYSTEM SPECIFICATIONS D Typical System Specifications PA microphone and manual switches Single CAN handset with PA microphone Single PWM handset with PA microphone via extension ...

Страница 7: ...n adaptor Application Software RSG has worked together with various clients to create a software package to suit their standard Emergency ServicesVehicles specification RSG ensures that all Universal Controllers supplied have their unique software package pre installed If you have Ford vehicles that require a Universal Controller please consult with RSG to ensure compatibility and be advised of th...

Страница 8: ...e units handsets keypads System intelligences The main control box can be used in it s standard format utilising the standard factory settings that are appropriate for most everyday hazard warning applications or can be customised either by RSG or the customer using the built in programming interface A full set of programming software is also available for special applications and technical users ...

Страница 9: ...ation with alternative PWM handsets RSG Engineering Limited Telephone 01543 438800 Fax 01543 438801 Email sales rsg ontop com Web www rsg ontop com 1 7 UNIVERSAL CONTROLLER CVS 012 USER GUIDE V2 G PRODUCT SPECIFICATION IN BRIEF G Product Specification in Brief POWER INPUTS CHANNELS A B UNIVERSAL HANDSET DISCONTINUED UNIVERSAL MULTI WAY HANDSET PLUS MCS T17 UNI HAP XXX UNIVERSAL MULTI WAY MIDI HAND...

Страница 10: ... 2 Output 5 CAN Data Monitor 1 6 Channel 6 7 Channel 3 8 CAN Data Monitor 2 9 Channel 7 Output 10 Channel 4 Output 11 Ground Common Ground 12 Channel 8 Output 13 CAN Data Monitor 3 14 CAN Data Monitor 4 15 N C USING THE SET UP MENU The LCD Display normally displays the status of the device So to enter the set up menu press and hold the Enter key until the display shows Set up Menu The menu will re...

Страница 11: ...ignals that mimic the operation of the unit PIN NAME FUNCTION 1 Channel 1 Monitor Output 2 Channel 2 Monitor Output 3 Channel 3 Monitor Output 4 Channel 4 Monitor Output 5 Channel 5 Monitor Output 6 Channel 6 Monitor Output 7 Channel 7 Monitor Output 8 Channel 8 Monitor Output 9 Channel 9 Monitor Output 10 Channel A Monitor Output 11 Channel B Monitor Output 12 Channel C Monitor Output 13 Channel ...

Страница 12: ... handsets keypads Bespoke programming required Best suited to customers who have a historic preference for a particular type of device However some bespoke programming and an alternative adaptor will be required Alternative handsets keypads must be procured and supplied by the customer or their agent RJ11 Extension Lead to Universal Controller CVS 012 Note Extension lead must always be used as it ...

Страница 13: ...VS 012 control system Main Features One of the most slimline range of switch units available in the market today Meets automotive protrusion regulations Fully programmable at source and or by customer Each switch can have a multi function HOT key action depending on required function Mini and Midi handsets have a built in microphone where button 2 is dedicated to act as optional PTT Push To Talk w...

Страница 14: ...on should be part of the combo group Optional Run Lock Button 5 7 is the only button that can be allocated for Run Lock use If you require Run Lock please write Run Lock in the legend field and place a tick in the Run Lock column Optional Button Beep Buttons can be programmed to have an audible beep when pressed as well as a reminder beep that sounds every 5 seconds when the button is activated Pl...

Страница 15: ...Lock column adjacent to the chosen button Optional Button Beep Buttons can be programmed to have an audible beep when pressed as well as a reminder beep that sounds every 5 seconds when the button is activated Please ensure that you tick the appropriate box below I DO require PTT Push to Talk I DO NOT require PTT Push to Talk I DO require an audible beep when buttons are pressed I DO require a rem...

Страница 16: ...ary When you are finished press and hold the large flashing button to move to page OPTIONS 1 Button Beep Press button to 1 Button Beep to activate button beep Green Activated Result all buttons will beep when pressed Warning Beep Press button to 2 Warn Beep to activate warning beep Green Activated Result the handset will beep every 5 seconds if any button is pressed Dim Bright Press button to 3 Di...

Страница 17: ... When you are finished press and hold the flashing button to move to page OPTIONS Button Beep Press button to 1 Button Beep to activate button beep Green Activated Result all buttons will beep when pressed Warning Beep Press button to 2 Warn Beep to activate warning beep Green Activated Result the handset will beep every 5 seconds if any button is pressed Dim Bright Brightest Press button to 7 Dim...

Страница 18: ...K OUTPUTS CHANNEL REF Left Alley A1 1 H L Flash A3 B1 5 9 Right Alley A7 3 360 A10 4 Front Blues B3 D Rear Blues A6 6 Grille Lights A9 7 Rear Reds A12 8 Sign B6 E Run Lock B10 C Front Spots B4 A Siren UNI CON 001 ONLY B7 B 999 Any combination of buttons At Scene Any combination of buttons Walk Test Activates each output in turn Reset Resets all active buttons REFER TO PROGRAMMING MANUAL TO ACTIVAT...

Страница 19: ...ght up next to the output pin on banks A and B when activated CONNECT PINS 5 8 11 14 TO GROUND VEHICLE EARTH 0 VOLTS RSG Engineering Limited Telephone 01543 438800 Fax 01543 438801 Email sales rsg ontop com Web www rsg ontop com 1 17 UNIVERSAL CONTROLLER CVS 012 USER GUIDE V2 K2 TYPICAL APPLICATION DRAWINGS K2 Typical Application Drawings Headlamp Flash Universal Multi Way Handset range also appli...

Страница 20: ...and Pin 1 on Bank B are active which can be confirmed by noticing the LED adjacent to them are illuminated Pressing the H L Flash switch again deactivates its operation As there are various Head Light Flash patterns available please refer to the relevant Installation Guide section for full details of this Handset Back Lighting Activation By operating the switch SWT3 connected to the Manual Control...

Страница 21: ... the auxiliary battery voltage is lower than the primary battery voltage and usually results in a blown fuse in the vehicle headlight circuit 2 Channel 5 and 9 Headlamp Diagram CORRECT configuration WITH auxiliary battery RSG Engineering Limited Telephone 01543 438800 Fax 01543 438801 Email sales rsg ontop com Web www rsg ontop com 1 19 UNIVERSAL CONTROLLER CVS 012 USER GUIDE V2 K2 TYPICAL APPLICA...

Страница 22: ...1 16 18 20 LIGHT HEAD 2 5 or 21w bulb 0V TO PIN 3 BANK B Note LED s light up next to the output pin on banks A and B when activated RSG Engineering Limited Telephone 01543 438800 Fax 01543 438801 Email sales rsg ontop com Web www rsg ontop com 1 20 UNIVERSAL CONTROLLER CVS 012 USER GUIDE V2 K3 TYPICAL APPLICATION DRAWINGS K3 Typical Application Drawings Siren Activation Basic wiring configuration ...

Страница 23: ...rating the Front Blues switch note this has a latching function on the handset Light Head 2 will then illuminate This indicates that Pin 3 on Bank B is active which can be confirmed by noticing the LED adjacent to it is illuminated Pressing the Front Blues switch again deactivates its operation By operating the switch SWT2 connected to the Manual Control Inputs will also illuminate Light Head 1 Th...

Страница 24: ...0 BANK B 0V 0V SWT 5 SWT 5 Note LED s light up next to the output pin on banks A and B when activated ACTIVATES BANK B PIN 10 CONNECT PINS 5 8 11 14 TO GROUND VEHICLE EARTH 0 VOLTS RSG Engineering Limited Telephone 01543 438800 Fax 01543 438801 Email sales rsg ontop com Web www rsg ontop com 1 22 UNIVERSAL CONTROLLER CVS 012 USER GUIDE V2 K4 TYPICAL APPLICATION DRAWINGS K4 Typical Application Draw...

Страница 25: ...s A and B on the main power feed connector is suitably fused For testing purposes 5 amps will be sufficient Warning Be sure to muffle the 100watt siren speaker output before sounding to protect hearing Run Lock Activation By operating the Run Lock switch note this has a momentary function on the handset Light Head 6 will then illuminate This indi cates that Pin 10 on Bank B is active which can be ...

Страница 26: ...technical skills some training is advisable in order to obtain the full benefits of this tool As such RSG can offer training for this facility at its premises that is normally Free of Charge for main motor dealers and installers Training is also available on site at customers premises however a nominal charge is normally made to cover expenses Although RSG can supply the software CD to suitably qu...

Страница 27: ... 1 Display Contrast Settings 8 4 2 Status Screens 9 5 Setup Menu 12 5 1 Menu Organisation 12 5 2 General Options 13 5 3 Factory Defaults 14 5 4 Output Channels Options 14 5 5 Save Settings 16 6 Wiring and Connections 17 6 1 Power Supply Connections 17 6 2 Bank A and Bank B Output Connector 18 6 3 Manual Control Inputs 19 6 4 Output Monitors 20 6 5 Special Function Inputs 21 6 6 Handheld Control Da...

Страница 28: ...CVS012 INSTALLATION GUIDE ...

Страница 29: ... Interface 8 4 1 Display Contrast Settings 8 4 2 StatusScreens 9 5 Setup Menu 12 5 1 MenuOrganization 12 5 2 General Options 13 5 3 Factory Defaults 14 5 4 Output ChannelOptions 14 5 5 SaveSettings 16 6 Wiring andConnections 17 6 1 Power SupplyConnections 17 6 2 Bank A and Bank B Output Connectors 18 6 3 Manual ControlInputs 20 6 4 Output Monitors 21 6 5 Special Function Inputs 22 6 6 Handheld Con...

Страница 30: ...should be rated to handle 15Amps or more The Split Sense line is used to provide power to the split charge data output This input should be protected with a fuse rated at 1 Amp 1 3 Digital Inputs 16 x Manual 12 x Special functions 1 x PTTswitch 1 4 Analog Inputs Mic PTT audio with adjustable volume control Radio audio with adjustable volume control Primary battery splitter charger sense 1 5 Analog...

Страница 31: ...itter charge primary sense input is used the input MUST be protected by a 1 Amp fuse preferably at or near to the primary battery terminal 2 3 DO NOT obstruct fan vents along the top side or under surfaces of the CVS012 Do not install any equipment on top or underneath the CVS012 The above installation requirement must be followed for safe operating and extended product lifetime ...

Страница 32: ...entitled Setup Menu for further information 3 1 3 Horn Ring Transfer The HRT system has two control inputs HRT Positive The HRT p signal is found on Pin 12 of the Special Function Inputs connector This input is active high This signal is typically connected to positive 13 8V switching Horncircuits HRT Negative The HRT n signal is found on Pin 14 of the Special Function Inputs connector This input ...

Страница 33: ...icrophone should be connected directly to Pin 1 of the Handheld Control Data Connector The microphone should be grounded using shielded cable and attached to the ground pin on the Handheld Control Data Connector To enable the PTT broadcast the PTT Switch Pin 6 on the Handheld Control Data Connector should be connected to ground 3 2 Runlock System The Runlock system is designed to maintain the igni...

Страница 34: ...would like to use and edit the MODE setting to show Runlock NOTE Any channel can be used for Runlock outputs and channel C can be used as any other type of output however using channel C and its associated diodes for Runlock outputs is the recommended configuration 3 3 Splitter Charger System The Splitter Charger system is designed to control a high current relay linking the secondary power batter...

Страница 35: ...c system is designed to inhibit specific outputs when a control signal is present Output channels 4 G and manual input 16 have been selected for use with the AND Logic system Functional Description If enabled when a high signal is present at manual input 16 outputs 4 and G will be inhibited turned off It is possible to reverse this feature and inhibit the outputs when the high signal is removed by...

Страница 36: ...rently the MHE RS485 and the S Link protocols are supported A star next tothe text indicates the CVS012 has detected RS485 and is communicating with the remotehandheld C Siren Mode This will show the state of the internal siren module D DIM This will show if the illumination input is active E Siren Current F Bank A Output Indicators Output is off Output is on D Voltage dropout has been exceeded X ...

Страница 37: ... and Low Turn Off Voltage Settings C Charge Status Indicates Split Data output is Onor Off A RS485 Remote Handheld Inputs B Generic Remote Handheld S LinkInputs C Manual Inputs D Special Function Inputs A Heatsink Temperature Shows Value in DegreesC and either FAULT or OK B Fan Status On or Off A CAN Bus Configuration Setting B CAN Status C Vehicle Speed if Available ...

Страница 38: ...r A Channel being viewed 1 9 A G B Output Status On or Off C Operating Mode D Dropout Voltage Value in brackets is theactual voltage for the channelselected E Over Current Value in brackets is theactual current for the channelselected F Delay Timer If the current channel is currently configured as an ignition of channel delay this indicator shows the amount of time remainingin the delay cycle G In...

Страница 39: ...o Tone 0 32 UK Yelp 0 32 UK Wail 0 32 Pulsar 0 32 Standard Two Tone 0 32 o Manual as Handheld On Off o Siren Auto Scroll On Off o Siren Auto Airhorn On Off o Siren Enable Start On Off o Delay Settings Ignition Delay A 0 240 minutes Ignition Delay B 0 240 minutes Channel Delay A 0 240 minutes Channel Delay B 0 240 minutes o AND Logic On Off o AND Inversion On Off o Siren Current Limit 5 19 5 Amps F...

Страница 40: ...sable this function or set the number of minutes required See 1 2 Runlock System 5 2 8 Splitter Charger Off This setting defines the Turn Off voltage levels for the Splitter Charger system See 1 3 Splitter Charger System 5 2 9 Splitter ChargerOn This setting defines the Turn On voltage levels for the Splitter Charger system See 1 3 Splitter Charger System 5 2 10 Siren Tones Standard Yelp Standard ...

Страница 41: ... 5 2 18 Siren CurrentLimit Set this to adjust the siren circuit current protection level This setting defaults to 15 Amps 5 3 Factory Defaults These menu options allow the operating parameters to be overwritten to preset factory defaults Several standard configurations are available Note Once the factory defaults have been applied the old settings are lost and cannot be recovered See Appendix 1 fo...

Страница 42: ...PentaPulse B 18 Medium PentaPulse with Pause A 19 Medium PentaPulse with Pause B 20 Fast PentaPulse A 21 Fast PentaPulse B 22 Fast PentaPulse with Pause A 23 Fast PentaPulse with Pause B 24 Cyclic Pattern A Note 1 25 Cyclic Pattern B Note 1 26 Ignition 27 Ignition Delay Setting A Note 2 28 Ignition Delay Setting B Note 2 29 Siren Enabled 30 Siren Data 31 Split Charge Data 32 System Bypass 33 Syste...

Страница 43: ...cond and then re activated If the current condition still exists after a further 400 milliseconds then that channel is disabled The only way to re enable the system is to reset the CVS012 5 4 4 Input Selection Each channel can respond to any of the sixteen handheld inputs In the menu the inputs are represented as 4 lines of 4 stars or dashes A star indicates that the channel will respond to an inp...

Страница 44: ...6 Wiring and Connections 6 1 Power Supply Connections Bank A 13 8VDC 40 Amps MAX Bank A supplies power to the Siren and outputs 1 8 Bank B 13 8VDC 40 Amps MAX Bank B supplies power to outputs 9 G ...

Страница 45: ...6 2 Bank A and Bank B Output Connectors Common Ground ...

Страница 46: ... 9 N C 10 Ground BANK B Name Pin 11 Manual 9 Input Channel 9 1 12 Manual 10 Input Channel A 4 13 Manual 11 Input Channel B 7 14 Manual 12 Input Channel C 10 15 Manual 13 Input Channel D 3 16 Manual 14 Input Channel E 6 17 Manual 15 Input Channel F 9 18 Manual 16 Input Channel G 12 All Inputs are Active High 12V When Use Manual Inputs as Handheld option is selected these inputs act the same as hand...

Страница 47: ...ut 7 Channel 7 Monitor Output 8 Channel 8 Monitor Output 9 Channel 9 Monitor Output 10 Channel A Monitor Output 11 Channel B Monitor Output 12 Channel C Monitor Output 13 Channel D Monitor Output 14 Channel E Monitor Output 15 Channel F Monitor Output 16 Channel G Monitor Output 17 Splitter Control Monitor Output 250mA Max 18 Siren Monitor Output 250mA Max 19 Runlock Monitor Output 250mA Max 20 Gr...

Страница 48: ...Enable Input Radio Control Active Low 10 Siren Enable Input Active High 11 System Disable Input Active High See Note 12 Horn Ring Transfer HRTp Input Positive Switched HRT Input 13 Air Horn Input Active Low Ground 14 Horn Ring Transfer HRTn Input Negative Switched HRT Input 15 Split Sense Input Primary Battery Voltage Input 16 Ground Common Ground Note System Disable has been implemented in the CV...

Страница 49: ...ion 1 Left Microphone Input 2 Ground Common 3 A RS485 Data 4 B RS485 Data 5 12VDC 12V Supply Output 250mA Max 6 Right PTT Sw PTT Active Low 6 7 CAN Bus Connector Pin Name Function 1 12V Output 500mA MAX 2 Ground 3 CAN Data Low Data 4 CAN Data High Data ...

Страница 50: ...6 8 Siren Speaker Connector Pin Name 1 Left 11 Ohm Speaker 2 11 Ohm Speaker 3 8 Ohm Speaker 4 Right 8 Ohm Speaker ...

Страница 51: ...A Steady On 12 5 Volts 10 Amps X B Steady On 12 5 Volts 10 Amps X C Steady On 12 5 Volts 10 Amps X D Steady On 12 5 Volts 10 Amps X E Steady On 12 5 Volts 10 Amps X F Steady On 12 5 Volts 10 Amps X G Steady On 12 5 Volts 10 Amps X Siren N A 12 5 Volts N A X Air Horn N A 12 5 Volts N A X Runlock N A N A N A Use Manual input as Handheld Off On Sidelight Cutout Off On Use Single Tap to Start Siren Of...

Страница 52: ...olts 10 Amps X B Steady On 12 0 Volts 10 Amps X C Steady On 12 0 Volts 10 Amps D Steady On 12 0 Volts 10 Amps X E Steady On 12 0 Volts 10 Amps F Steady On 12 0 Volts 10 Amps X G Steady On 12 0 Volts 10 Amps Siren N A 12 0 Volts N A X Air Horn N A 12 0 Volts N A X Runlock N A N A N A Use Manual input as Handheld Off On Sidelight Cutout Off On Use Single Tap to Start Siren Off On Handheld Selection ...

Страница 53: ...ntaPulse Slow B 12 0 Volts 12 5 Amps X B PentaPulse Slow A 12 0 Volts 12 5 Amps X C PentaPulse Slow B 12 0 Volts 12 5 Amps X D Steady On 12 0 Volts 12 5 Amps E Steady On 12 0 Volts 12 5 Amps F Steady On 12 0 Volts 12 5 Amps G Steady On 12 0 Volts 12 5 Amps Siren N A 12 0 Volts N A X Air Horn N A 12 0 Volts N A Runlock N A N A N A Use Manual input as Handheld Off On Sidelight Cutout Off On Use Sing...

Страница 54: ...a simple flash pattern running at 90 Beats per Minute 1 5 Hz The on and off times are symmetrical 50 Duty Cycle and are 333 milliseconds long When Output A is on Output B is off and visa versa 8 3 120 BPM Alternating A B This is a simple flash pattern running at 120 Beats per Minute 2 Hz The on and off times are symmetrical 50 Duty Cycle and are 250 milliseconds long When Output A is on Output B i...

Страница 55: ...8 7 Fast PentaPulse A B 8 8 Slow PentaPulse with Pause A B 8 9 Medium PentaPulse with Pause A B 8 10 Fast PentaPulse with Pause A B ...

Страница 56: ...9 Appendix C Application Diagrams 9 1 Split Charging Diagram ...

Страница 57: ... Amps A _ Volts _ Amps B _ Volts _ Amps C _ Volts _ Amps D _ Volts _ Amps E _ Volts _ Amps F _ Volts _ Amps G _ Volts _ Amps Siren N A _ Volts N A Air Horn N A _ Volts N A Runlock N A N A N A Use Manual input as Handheld Off On Sidelight Cutout Off On Use Single Tap to Start Siren Off On Handheld Selection None MHE RS485 Generic Handheld Backlight Off On Auto Buzzer Off On Editing Locked Off On Si...

Страница 58: ...Added new menu layout Added screen shots for status pages Revised contents page Added AND Logic description Added Specification section Added Installation Requirements section 13 Jul 2009 13 July 2009 14 Jul 2009 16 Jul 2009 16 Jul 2009 16 Jul 2009 16 Jul 2009 2 27 Added siren current limit adjustment to system menu 03 August 2009 Added splitter charger application diagram to the appendix 03 Augus...