3. Channel 5 and 9 (Headlamp) Diagram -
INCORRECT
configuration
WITH
auxiliary battery
NOTE 1
The
BOLD
circuit path shows the reverse current flow
that can occur when the headlight circuit is activated.
This current will flow when the auxiliary battery voltage
is lower than the primary battery voltage and usually
results in a blown fuse in the vehicle headlight circuit.
2. Channel 5 and 9 (Headlamp) Diagram -
CORRECT
configuration
WITH
auxiliary battery