6 ROTEX control system ALPHA
+
23R
47
FA ROTEX ESU - 07/2008
6.6.6 Automatic summer switch-off
This function only has an effect in the
,
and
automatic programmes.
• Set the summer switch-off temperature by changing parameter [29].
6.6.7 Setting hot water mode
Activating and deactivating hot water mode
• You activate and deactivate hot water mode manually by changing parameter [2].
Ta
External temperature
T
V
Flow temperature
T
R
Room temperature
Fig. 6-17 Heating characteristic curve
If the external temperature exceeds the set
summer switch-off temperature
, the
heating circuits
will be
deactivated automatically
; i. e. the pumps are switched off, the mixer closed and the switch valve switched
to warm water.
CAUTION:
If the Legionella protection function is activated, the hot water temperature may temporarily exceed 65 °C.
• If hot water is required during the disinfection phase, it must be mixed with cold water.
If the ROTEX ALPHA
+
23R detects a storage tank sensor on ROTEX ESU start-up, the warm water mode is
activated automatically. If a storage tank sensor is connected subsequently, the hot water function must be
activated via parameter [2].
25
35
45
55
65
75
85
95
105
-20
-15
-10
-5
0
5
10
15
20
25
0,50
0,20
0,75
1,00
1,25
1,50
1,75
2,00
2,25
2,50
2,75
3,00
3,25
3,50
T (°C)
a
T (°C)
R
T
(°C)
V
30
20
15
10