Installation Instructions ROTARY inground lifts SL230/SL235/SL2
50 • Release: 11/2013 • Page 11
5.3 Installation of pneumatic emergency system
The pneumatic emergency system allows lowering of the lift in case of power failure. Also lead the delivered
pneumatics hose
4x1 mm of the power unit through the empty tube to the control unit (already at works pre-
assembled). Lead the pneumatic hose through the smallest cable gland there into the case and embed it onto the
planned compressed-air inlet from the inside (fig. 10).
Fig. 10 Connection of the pneumatic pipe
5.4 Adjustment of the proximity switches (NAMUR)
The NAMUR-switches (inductive switches) are pre-adjusted completely at factory (fig. 11). Normally there is no use
for further adjustment.
Fig. 11: Both NAMUR-switches
installed for use.