Enclosure: Error code of the control
Code Error message in the
terminal software
Description
0
no error.
No error at all.
1
I2C bus blocked!
The I2C bus to the configuration EEPROM is not working. Exchange
Piggy Board.
2
pointer init
No error: The history log for all error events was initiated for the first
time.
8
I2C bus blocked!
The I2C bus to the configuration EEPROM is not working. Exchange
Piggy Board.
9
I2C bus blocked!
The I2C bus to the configuration EEPROM is not working. Exchange
Piggy Board.
11
I2C bus blocked, tx-buffer
full!
The I2C bus to the configuration EEPROM is not working. Exchange
Piggy Board.
12
I2C bus blocked!
The I2C bus to the configuration EEPROM is not working. Exchange
Piggy Board.
13
invalid parameter sum!
The checksum over the parameters stored within the configuration
EEPROM is invalid.
Enter Servicemenue and recalculate checksum. If not successful,
exchange Piggy-Back board.
14
invalid model type!
The magic number stored in the configuration EEPROM is unknown.
Either it was changed by mistake or the EEPROM is damaged. Enter
servicemenue and restore the right magic number or exchange Piggy
Board if not successful
15
eeprom chip damaged!
The I2C bus to the configuration EEPROM is not working. Exchange
Piggy Board
16
piggy back board not
working!
The analog multiplexer IC on the Piggy Board does not find the pullup
resistor. Either Piggy Board is not working or CPU is damaged.
Exchange first Piggy Board then try another Control Board.
17
software hangup, stopped! There was a reset initiated by the watchdog, checking if the controller
firmware is still alive. This error may happen if the keyswitch is quickly
reswitched on. The supply voltage had no time to go down enough. If
this error happens during normal operations, the CPU or at least the
firmware in it is damaged. Exchange the Control Board.
18
ballance safety circuit on
The redundant ballance safety circuit noticed a large difference between
the left and right cylinders. If it is no „electronic ballance“ type of carlift,
check if the socket for the ballance circuit on the Piggy Back Board is
empty. Next enter the Servicemenue and check the values of the
cylinder heights. Maybe the potis need to be readjusted.
19
analog reference voltage
to low!
The 5Volt supply is not ok. Check for a short circuit on the poti
cables. Next exchange the Piggy Board. If error persists, exchange
Control Board.
20
namur supply voltage too
low!
The 15Volt supply for the namur switches is not ok. Exchange
the Control Board.
21
upwards speed too high!
The limit for the upwards speed was exceeded. Call the Servicemenue
and check this limit.
Содержание SL230RA-PE
Страница 25: ...Installation Instructions ROTARY inground lifts SL230 SL235 SL250 Release 11 2013 Page 25 ...
Страница 26: ...Installation Instructions ROTARY inground lifts SL230 SL235 SL250 Release 11 2013 Page 26 ...
Страница 27: ...Installation Instructions ROTARY inground lifts SL230 SL235 SL250 Release 11 2013 Page 27 ...
Страница 28: ...Installation Instructions ROTARY inground lifts SL230 SL235 SL250 Release 11 2013 Page 28 ...
Страница 29: ...Installation Instructions ROTARY inground lifts SL230 SL235 SL250 Release 11 2013 Page 29 ...
Страница 30: ...Installation Instructions ROTARY inground lifts SL230 SL235 SL250 Release 11 2013 Page 30 ...