Follow these steps to install the temperature sensor tube:
1. Mount the anchor weight on the tube.
2. Mount the tube so that the threads at the top of the tube fits the nozzle
flange as illustrated in Figure 3-5:
Figure 3-5. Adjusting the
temperature sensor tube
3. When the tube is placed on the nozzle, adjust the position with the lock
nuts. If the weight is placed at the end of the tube, it should barely touch
the tank bottom.
4. Install the Rosemount 2240S Multi-Input Temperature Transmitter, see
“Mechanical Installation” on page 4-3.
NOTE
Ensure that the flexible protection tube is in a vertical position to obtain correct
measurement data.
Locknut
Tube
Anchor
weight
Threads
Locknut
2.5-15 kg
(5.5-33 lbs)
85-330 mm
(33-130 in.)