Reference Manual
300550EN, Rev AA
December 2010
3-5
Rosemount 2240S
Section 3. MST/WLS Installation
3.3.2
Installation on
Floating Roof
Tanks
On floating roof tanks the temperature elements can be mounted in a still-pipe
as illustrated in Figure 3-2 or in other suitable roof openings.
Figure 3-2. Installation of
multiple spot temperature
elements in still-pipe
0.5-1 m
(1.6-3.2 ft)
0.5-1 m
(1.6-3.2 ft)
Maximum level
Upper spot
element
First spot
element
2.5-4 kg
(5.5-8.8 lbs)
100 mm
(3.9 in.)