A.1 SPECIFICATIONS
General
Product
Rosemount 2240S Multi-Input Temperature Transmitter
Number of spot elements and wiring
Up to 16 RTD spot elements or averaging sensors can be connected to a 2240S.
Rosemount temperature / water level sensors (models 565, 566 and 765)
Three wiring types can be used:
• 3-wire
RTD with common return (1-16 spot elements)
• 3-wire RTD individual (1-16 spot elements with Rosemount 565, 1-6 spot elements
with Rosemount 566, and 1-14 spot elements with Rosemount 765)
• 4-wire RTD individual (1-16 spot elements with Rosemount 565, 1-4 spot elements
with Rosemount 566, and 1-10 spot elements with Rosemount 765)
Standard temperature sensor types
Supports Pt-100 (according to IEC/EN60751, ASTM E1137) and Cu-90
Metrology sealing possibility
Yes
Write protect switch
Yes
Hazardous location certifications
ATEX, FM-C, FM-US, and IECEx.
CE-mark
Complies with applicable EU directives (EMC, ATEX)
Ordinary location certification
Complies with FM 3810:2005 and CSA: C22.2 No. 1010.1
Measuring Performance
Temperature conversion accuracy
(1)
±0.05 °C (±0.09 °F)
Ambient temperature effect
±0.05 °C (±0.09 °F)
Temperature measuring range
Supports -200 to 250 °C (-328 to 482 °F) for Pt-100
Resolution
± 0.1 °C (± 0.1 °F) according to API chapter 7 and 12
Update time
4 s
Configuration
Configuration tool
TankMaster WinSetup is the recommended tool for easy configuration of 2240S.
The Tankbus autoconfiguration feature, handled by the Rosemount 2410 Tank Hub,
supports 2240S
Configuration parameters (examples)
Temperature:
• Number of temperature sensor elements
• Temperature element type (spot or average)
• Temperature element position in tank
Water Level Sensor:
• Level offset (difference between tank zero level and water zero level)
• Probe length (autoconfigured by Rosemount 765)
Output variables and units
Spot and average temperature: °C (Celsius), and °F (Fahrenheit)
Free water level (FWL): meter, centimeter, millimeter, feet, or inch
Содержание 2240S
Страница 2: ......
Страница 4: ......
Страница 58: ...Reference Manual 300550EN Rev AA December 2010 Rosemount 2240S 5 16 Section 5 Configuration Operation ...
Страница 84: ...Reference Manual 300550EN Rev AA December 2010 Rosemount 2240S A 6 Appendix A Reference Data ...
Страница 96: ...Reference Manual 300550EN Rev AA December 2010 Rosemount 2240S B 12 Appendix B Product Certifications ...
Страница 99: ......