Chapter 2 Installation
Accura 2300/2350 User Guide
Page 86
ⓒ
2011 Rootech Inc. All Rights Reserved
Accura 2350 Single-phase Single-hole Power Measuring Module Through-hole Wiring
Accura 2350-1PSCSH Split-core Power Measuring Module Current Input
Item
Description
Connector type
Through-hole
Wire
Select corresponding to through-hole size
Measuring range
Model
Minimum
Measurement
Measuring Range
[Accuracy guaranteed
1
]
Accura 2350-1PSCSH-800A
0.80A
3.20A - 960A
Accura 2350-1PSCSH-630A
0.63A
2.52A - 756A
Accura 2350-1PSCSH-400A
0.40A
1.60A - 480A
Impedance
Not applicable because it is through-hole structure
Frequency range
42 - 69Hz
Hole size
Model
Size
Weight
[through-hole]
Accura 2350-1PSCSH-800A
43.9 x 45.1 mm
569g
Accura 2350-1PSCSH-630A
33.5 x 41.2 mm
383g
Accura 2350-1PSCSH-400A
33.5 x 41.2 mm
383g
1. Current accuracy meets ± 0.2% RD error and power/energy conforms to IEC62053-22 Class 0.2S.