1. Apply 115VAC or 230VAC to the Smart Controller (as appropriate), then turn the rocker switch to the On position.
2. Press and hold the Mode button on the Smart Controller for five seconds to engage Program Mode (see Section 3.8.1).
3. "P1" (Close Time Delay) will appear on the Display Indicator. Verify its value is consistent with your requirements.
4. Press and release the Mode button until "P20" (Open Input Function) is displayed. Verify its value is consistent with your
requirements.
5. Cycle to P22 (Auxiliary Safety Response). Verify its value is consistent with your requirements.
6. Cycle to program parameter PS1 (Change Program Limits).
7. Press the Up arrow button until "Yes" is displayed.
8. Press the Mode button again. "PS2" (Set Open Limit) will be displayed.
9. The door will proceed to the open limit, then stop. Once the door stops, adjust the open limit using the Up and Down arrow
buttons. It is normally set flush with the bottom of the top bar of the head unit.
10. Press the Mode button again. "PS3" (Set Closed Limit) will be displayed.
11. The door will proceed to the closed limit, then stop. Once the door stops, adjust the closed limit using the Up and Down arrow
buttons. It is normally set where the panel touches the floor but the center panel is not slack.
12. Press the Mode button again. The Smart Controller will exit Program Mode.
13. Press the Open button on the outside switch. If the door is set to close automatically, it will do so as long as the safety beam
(see Section 3.4) is unobstructed. If the door is set to close manually, press the Close button on the outside switch.
14. Press the Open button (and the Close button if necessary) a few times to verify the door opens and closes properly.
15. Repeat Steps 13 and 14 on the inside switch.
16. Verify the door stops (and reverses if configured to do so) when the safety beam is interrupted while the door closes.
17. Verify the leading edge switch (see Section 3.3) is operational.
18. Verify the door movement LEDs function properly.