4801-5164J
20 October 2021
17
RS-500 5K Walk-In Cooler Door Installation and Operation Manual
1. Drill a 1" hole in the wall in line with the 1" hole in the back of the right track, approximately 4' above the floor.
2. Route the harness from the back to the front through the hole you just drilled.
3. Apply sealant (ideally waterproof silicone; not included) around the harness from the back.
NOTICE:
If the sealant is not applied or is applied incorrectly, condensation can form inside the switch enclosure.
4. On the inside of the door, center the Wave Switch bracket over the 1" hole in the base of the enclosure (orienting it with the
flanges at the top and bottom), then mount the enclosure to the wall using four screws. Ensure the enclosure remains level.
5. On the outside of the door, position the right track cladding next to the track frame.
6. Route the harness through the holes, then plug the two connectors into the corresponding receptacles on the front Wave
Switch.
7. Apply one of the "Moving Door" labels (4501-6312) 3" above the switch enclosure.
Section 2.6.1: Interior Wave Switch
Section 2.6: Install Switches and Infrared Safety Beam System