5. Troubleshooting
112
Message
Cause
Solution
123: "When doing reset, carriage
encoder signal is reversed."
"Please confirm interlock switch
and restart software. If the
device do not recover, please
contact your equipment
provider."
•
The machine's front cover
or another cover is open.
•
The carriage is positioned
too far to the left or right
end.
•
Close the cover properly,
and then reboot Print
Control.
•
Move the carriage by hand
approximately 10 cm
toward the center, and then
reboot Print Control.
If the same message appears
even after this is performed, turn
the machine off and on. If the
same message still appears,
contact your authorized Roland
DG Corporation representative.
124: "Both of left and right limit
switches are in effective
condition."
"Contact your equipment
provider, please!"
There is a problem with the
carriage system of the machine.
Turn the power to the machine
off and then on again. If the same
message still appears, contact
your authorized Roland DG
Corporation representative.
125: "The emergency stop has
been pressed."
"Twist emergency switch, then
restart software."
The emergency stop button on
the machine was pressed.
Close Print Control, and then
release the emergency stop
button. Turn the power to the
machine off and then on again,
and then restart Print Control. For
details about how to release the
emergency stop button, see
126: "Both Y limit switch signals
are valid."
"Contact your equipment
provider, please!"
There is a problem with the
carriage system of the machine.
Turn the power to the machine
off and then on again. If the same
message still appears, contact
your authorized Roland DG
Corporation representative.
127: "Y position encoder no
signal"
"Contact your equipment
provider, please!"
There is a problem with the
carriage system of the machine.
Turn the power to the machine
off and then on again. If the same
message still appears, contact
your authorized Roland DG
Corporation representative.
Содержание IU-1000F
Страница 2: ......
Страница 6: ...4 ...
Страница 22: ...1 Getting Started 20 As seen from the back of the machine ...
Страница 54: ...3 Basic Operations 52 If the ink configuration is set to Double White Ink Config ...
Страница 84: ...4 Convenient Usage 82 ...
Страница 122: ...5 Troubleshooting 120 ...
Страница 138: ...6 Maintenance and Specifications 136 ...
Страница 142: ...140 MEMO ...
Страница 143: ......
Страница 144: ...R2 191227 1000022481 2019 Roland DG Corpora on November 2019 M0DW7016 ...