EN
70
10.3
TEST mode
8LI8)78QSHIMWYWIHXSXIWXEGXMZEXMSRSJXLIGSQQERHWERHWEJIX]HIZMGIW[MXLZMWYEPGSRƼVQEXMSR
To activate the mode, press the TEST button with the automatic door system at rest. If the gate is moving, pressing
TEST stops the gate. Pressing the button again enables TEST mode.
-JXLIƽEWLMRKPMKLXERHXLIKEXISTIRMRHMGEXSVPEQTMPPYQMREXIJSVSRIWIGSRHIEGLXMQIEGSRXVSPMWYWIHSVE
safety device is activated.
The command signal status is shown on the left hand side of the
display for 5 seconds, ONLY when the respective command signal is
active (AP, CH, PP, PE, OR). For example, if the gate open command is
activated, the letters AP appear on the display.
The status of the safety devices/inputs is shown on the right hand
side of the display. The number of the terminal relative to the safety
HIZMGIMREPEVQWXEXIƽEWLIW
When the gate is completely open or completely closed,
)$
or
)&
is
shown on the display to indicate that the gate has reached the gate
open limit switch
)$
or gate closed limit switch
)&
.
Example
: STOP contact in alarm state
No safety device in alarm state and no limit switch activated.
6E
(Sb)
Release handle or lock open.
STOP contact (N.C.) open.
If there is no STOP switch, jumper the contact.
Sensing edge contact COS1 (N.C.) is open. Check connection.
If sensing edge is not installed, disable with
.
Sensing edge contact COS2 (N.C.) is open. Check connection. If sensing
edge is not installed, disable with
.
Photocell contact FT1 (N.C.) is open. Check connection. If photocell is not
installed, disable with
.
Photocell contact FT2 (N.C.) is open. Check connection. If photocell is not
installed, disable with
.
IH
Both limit switches in error state.
Check connections and settings of limit switches.
ID
If gate is open, gate open limit switch is detected.
I&
If gate is closed, gate closed limit switch is detected.
NOTA
: If one or more contacts are open, the gate will not open or close. This does not apply for the limit switch
signal state, however, which is shown on the display but does not prevent normal operation of the gate.
-JQSVIXLERSRIWEJIX]HIZMGIMWMREPEVQWXEXISRGIXLITVSFPIQVIPEXMZIXSXLIƼVWXHIZMGIMWVIWSPZIHXLIEPEVQ
for the next device is displayed. Any further alarm states are also displayed with the same logic.
Press the TEST button again to exit test mode.
After 10 seconds with no user input, the display returns to command and safety device state display mode.
10.4
Standby mode
8LMWQSHIMWEGXMZEXIHEJXIVQMRYXIW[MXLRSYWIVMRTYX8LI43;)60)(ƽEWLIWWPS[P]
Press UP
a
, DOWN
b
,
+
or
-
to reactivate the control unit.
POWER
NOTE: If a safety password (only if active) is unlocked, to adjust the
parameter settings, the password is automatically reactivated in
Stand By mode.
Содержание B70/1DC
Страница 4: ...4 FW r1 65 ...
Страница 5: ...5 1 BH30 BM30 A A A A B A A B ...
Страница 6: ...6 A B A 2 4 5 BH30 Scheda ricarica batteria B71 BC B71 BC battery charger ...
Страница 8: ...8 4 BH30 CAVO MOTORE MOTOR CABLE ...
Страница 20: ...20 17 PR1 PR2 L1 L2 PR1 PR2 Canali radio Radio channels ...
Страница 21: ...21 n e ro b la c k gr igi o g rey 18 BH30 ...
Страница 22: ...22 19 BM30 n e r o b l a c k grigio gre y ...