![Roger Technology B70/1DC Скачать руководство пользователя страница 73](http://html.mh-extra.com/html/roger-technology/b70-1dc/b70-1dc_instruction-and-warnings-for-the-installer_1477299073.webp)
EN
73
12
Index of parameters
PARAM.
FACTORY
DEFAULT
DESCRIPTION
PAGE
$
see chap. 13
Selecting automation system model
75
$
Automatic closure after pause time (from gate completely open)
75
$
Automatic gate closing after mains power outage
75
$
Selecting step mode control function (PP)
75
$
4VIƽEWLMRK
75
$
Condominium function for partial open command (PED)
75
$
Enabling operator present function.
76
$
Gate open indicator / photocell test function and “battery saving”
76
Setting deceleration during opening (and closing for
BH30/600-BH30/800-
BM30/400
)
76
Setting deceleration during closing (
High Speed and Reversible Series
only)
76
Setting gate open limit switch constant speed approach distance
76
Setting gate closed limit switch constant speed approach distance
76
Partial opening adjustment (%)
76
COR output operating mode
76
Setting automatic closing time
76
Enabling of management for opening with automatic re-closure exclusion.
77
Setting reverse time after activation of sensing edge or obstacle detection
(crush prevention).
77
Setting motor torque
77
Setting obstacle impact force sensitivity
77
Setting start acceleration during opening (and closing for
BH30/600-
BH30/800- BM30/400
)
77
Setting start acceleration during closing (
High Speed and Reversible Series
only)
77
Enabling maximum torque boost at start of manoeuvre
77
Setting motor torque during position recovery
78
Setting opening speed (%) (and closing for
BH30/600-BH30/800-
BM30/400
)
78
Setting closing speed (%) (
High Speed and Reversible Series
only)
78
Setting end of manoeuvre constant approach speed
78
Setting number of automatic closure attempts after activation of sensing
edge or obstacle detection (crush protection)
78
Setting photocell mode during gate opening (FT1)
78
Setting photocell mode during gate closing (FT1)
78
Photocell (FT1) mode with gate closed
78
Setting photocell mode during gate opening (FT2)
79
Setting photocell mode during gate closing (FT2)
79
Photocell (FT2) mode with gate closed
79
Enable close command 6 s after activation of photocell (FT1-FT2)
79
Setting motor stop distance
79
Selecting installattion position of motor relative to gate (seen from interior side)
79
'SRƼKYVMRKWIRWMRKIHKI'37
79
'SRƼKYVMRKWIRWMRKIHKI'37
79
Содержание B70/1DC
Страница 4: ...4 FW r1 65 ...
Страница 5: ...5 1 BH30 BM30 A A A A B A A B ...
Страница 6: ...6 A B A 2 4 5 BH30 Scheda ricarica batteria B71 BC B71 BC battery charger ...
Страница 8: ...8 4 BH30 CAVO MOTORE MOTOR CABLE ...
Страница 20: ...20 17 PR1 PR2 L1 L2 PR1 PR2 Canali radio Radio channels ...
Страница 21: ...21 n e ro b la c k gr igi o g rey 18 BH30 ...
Страница 22: ...22 19 BM30 n e r o b l a c k grigio gre y ...