Enabling operator present function.
Disabled.
Enabled. The open (AP) or close (CH) button must be pressed continuously to operate the gate. The gate stops
when the button is released.
Equipped with safety function according to standard EN ISO 13849.
To open the gate, press the AP command, release it and then press it again, holding it pressed. The gate stops
when the button is released.
To close the gate, press the CH command, release it and then press it again, holding it pressed. The gate stops
when the button is released.
D
Gate open indicator / photocell test function and “battery saving”
The indicator is off when the gate is closed, and steadily lit during manoeuvres and when the gate is open.
8LIMRHMGEXSVƽEWLIWWPS[P]HYVMRKSTIRMRKQERSIYZVIWERHMWPMXWXIEHMP][LIRXLIKEXIMWGSQTPIXIP]STIR-X
ƽEWLIWUYMGOP]HYVMRKGPSWMRKQERSIYZVIW
If the gate is stopped in an intermediate position, the lamp extinguishes twice every 15 seconds.
Set
MJXLISYXTYX7'MWYWIHJSVXLITLSXSGIPPXIWX7IIƼK
Set to
MJXLISYXTYX7'MWYWIHJSVXLIƈFEXXIV]WEZMRKƉJYRGXMSR7IIƼK
When the gate is completely open or closed, the controller unit deactivates any accessories connected to terminal
SC to reduce battery consumption.
Set to
MJXLISYXTYX7'MWYWIHJSVXLIƈFEXXIV]WEZMRKƉJYRGXMSRERHTLSXSGIPPXIWXJYRGXMSR7IIƼK
Setting deceleration during opening and closing
See chapter 14-15 "Special parameters for High Speed and Reversible series"
= the gate decelerates near the limit switch ...
= the gate decelerates long before the limit switch.
Setting gate open limit switch constant speed approach distance
N.B.:
the manoeuvre speed is set with parameter
. After decelerating, the gate completes the distance to the
limit switch at constant speed.
Setting gate closed limit switch constant speed approach distance
N.B.:
the manoeuvre speed is set with parameter
. After decelerating, the gate completes the distance to the
limit switch at constant speed.
= Approximate 15 cm distance; ...
= Approximate 30 cm distance; ...
= Approximate 120 cm distance.
Partial opening adjustment (%)
N.B.
: This parameter is set to 50% (half of total gate travel) by default.
From 10% to 99% of total gate travel.
COR output operating mode
STANDARD operation managed by parameter
Closed contact if the release handle is correctly closed (with the key turned to closed position).
Open contact due to a fault: Motor released and/or key turned to open position.
Contact closed if the motor is powered by the mains or charged battery.
Open contact due to a fault: Motor powered by low battery (voltage level set by par.
) or with error alert
EW/2
(the control unit no longer accept commands).
Closed contact if none of the fault related situations 1 and 2 occurs.
Open contact if at least one of the fault related situations 1 and 2 occurs
Closed contact if the gate is not completely open.
Open contact if the gate is completely open.
Closed contact if the gate is not completely closed.
Open contact if the gate is completely closed.
Setting automatic closing time
The timer starts from the gate open state and continues for the set time. Once the set time is reached, the gate
closes automatically. The timer count restarts if a photocell is triggered.
Pause time settable from 00 to 90 s.
Pause time settable from 2 to 9 min.
Содержание B70/1DC
Страница 4: ...4 FW r1 65 ...
Страница 5: ...5 1 BH30 BM30 A A A A B A A B ...
Страница 6: ...6 A B A 2 4 5 BH30 Scheda ricarica batteria B71 BC B71 BC battery charger ...
Страница 8: ...8 4 BH30 CAVO MOTORE MOTOR CABLE ...
Страница 20: ...20 17 PR1 PR2 L1 L2 PR1 PR2 Canali radio Radio channels ...
Страница 21: ...21 n e ro b la c k gr igi o g rey 18 BH30 ...
Страница 22: ...22 19 BM30 n e r o b l a c k grigio gre y ...