Electrical connections
A switch or an omnipolar cut-off switch with a contact opening of at least 3 mm must be
installed on the mains power line; put the cut-off switch in OFF position and disconnect any
buffer batteries before performing any cleaning or maintenance operations.
Ensure that an adequate residual current circuit breaker with a 0.03 A threshold and a
suitable overcurrent cut-out are installed upstream the electrical installation in accordance
with best practices and in compliance with applicable legislation.
For power supply, use a H07RN-F 3G1.5 type electric cable and connect it to the terminals L
(brown), N (blue), (yellow/green), located inside the automation system.
Strip the insulation from the ends of the power cable wires which will be connected to the
terminal (see ref.
D
ƼKERHWIGYVIXLIGEFPI[MXLXLIGEFPIVIXEMRIV
Measure the voltage on the primary mains power connection with a tester.
A
V
V
A
+
-COM
220÷230
N
L
FUSE
TRANSFORMER
For the Brushless automation system to function correctly, the mains
power voltage must be:
- 230Vac ±10% for the B70/1DC control unit.
- 115Vac ±10% for the B70/1DC/115 control unit.
-JXLIHIXIGXIHZEPYIHSIWRSXGSQTP][MXLXLIEFSZIWTIGMƼIHZEPYIW
SVMWRSXWXEFPIXLIEYXSQEXMSRW]WXIQQE]238STIVEXIIƾGMIRXP]
Connections to the electrical distribution network and to any other low-voltage
conductors in the external section to the electrical panel must be on an independent
path and separate from the connections to the command and safety devices (SELV =
Safety Extra Low Voltage).
Make sure that the mains power conductors and the accessory wires (24 V) are separated.
The cables must be double insulated, strip them near the relevant connection terminals and
lock them with clamps (not supplied).
DESCRIPTION
FUSE
N
L
Mains power supply 230 Vac ±10% (115 Vac ±10%) connection.
Fuse 5x20 T1A.
B70/1DC/115:
Fuse 5x20 T2A.
POWER IN
4
5
Power feed input from transformer (or from
B71/BC
battery charger
- only BH30
series -
MJYWIHƼK
N.B.: Ready wired in factory by ROGER TECHNOLOGY.
WARNING! With the board powered the battery connected, pay maximum attention
XSXLITSPEVMX]WIIƼK
X-Y-Z
M
X Y
Z
Connection to ROGER brushless motor.
Connecting
B72/BRAKE / B72/BRCL
controller for
&, ,MKL 7TIIH ƼK ERH
&1,MKL7TIIHZIVWMSRWƼK
N.B.: Ready wired in factory by ROGER TECHNOLOGY.
Warning! If the motor wires become disconnected from the terminal board, after
reconnecting correctly, the gate travel must be acquired again as described in
GLETXIV
Содержание B70/1DC
Страница 4: ...4 FW r1 65 ...
Страница 5: ...5 1 BH30 BM30 A A A A B A A B ...
Страница 6: ...6 A B A 2 4 5 BH30 Scheda ricarica batteria B71 BC B71 BC battery charger ...
Страница 8: ...8 4 BH30 CAVO MOTORE MOTOR CABLE ...
Страница 20: ...20 17 PR1 PR2 L1 L2 PR1 PR2 Canali radio Radio channels ...
Страница 21: ...21 n e ro b la c k gr igi o g rey 18 BH30 ...
Страница 22: ...22 19 BM30 n e r o b l a c k grigio gre y ...