Travel acquisition
For the system to function correctly, the barrier travel must be acquired by the controller.
11.1
Before starting:
IMPORTANT:
Select the automation system model installed with the parameter
$
.
KEY:
HIGH SPEED Motors
Reversible Motor
SELECTION
MODEL
MOTOR TYPE
CONFIGURATION
D
BH30/600
/
/
D
BH30/800
/
/
D
BH30/500/HS
BH30/600/HS
see chapter 14 "Special Parameters for High Speed Motor"
D
BM30/400
/
D
BM30/300/HS
see chapter 14 "Special Parameters for High Speed Motor"
D
BH30/804/R
see chapter 15 "Special Parameters for Reversible Motor"
1. Select the position of the motor relative to the gate with the parameter
. The default setting for this parameter
is with the motor installed on the right hand side of the gate (seen from interior side).
LEFT OPENING
RIGHT OPENING
2. Adjust the (mechanical or magnetic) limit switches so that, once triggered, the gate stops slightly before it
reaches the mechanical stop.
CLOSING LIMIT SWITCH
OPENING LIMIT SWITCH
3. Check that the operator present function is not enabled (
$
).
OPEN
CLOSE
STOP
4. Move the gate into the closed position.
5. Press
TEST
(see TEST mode in chapter 10) and check the command signal and safety device states. If any
safety devices are not installed, jumper the relative contact or disable the device from the relative parameter
(
,
,
,
,
and
).
Содержание B70/1DC
Страница 4: ...4 FW r1 65 ...
Страница 5: ...5 1 BH30 BM30 A A A A B A A B ...
Страница 6: ...6 A B A 2 4 5 BH30 Scheda ricarica batteria B71 BC B71 BC battery charger ...
Страница 8: ...8 4 BH30 CAVO MOTORE MOTOR CABLE ...
Страница 20: ...20 17 PR1 PR2 L1 L2 PR1 PR2 Canali radio Radio channels ...
Страница 21: ...21 n e ro b la c k gr igi o g rey 18 BH30 ...
Страница 22: ...22 19 BM30 n e r o b l a c k grigio gre y ...