Rockwell Automation Publication 2198-RM004C-EN-P - March 2022
53
Chapter 4 Dimensions, Cables, and Wiring
Kinetix 5100 Servo Drives Power Wiring Examples
This section provides wiring examples to assist you in wiring the Kinetix 5100
servo drive system. Drawing notes are listed after the drawings.
Three-phase Power Wired to Three-phase Kinetix 5100 Drives
This example illustrates grounded three-phase power that is wired to three-
phase Kinetix 5100 drives when phase-to-phase voltage is within drive
specifications. You must supply input power components. The three-phase AC
line filter is wired as shown in
Figure 27 - Kinetix 5100 Drive Three-phase (200…230V) Grounded Power Configuration (wye
secondary)
Figure 28 - Kinetix 5100 Drive Three-phase (380…480V) Grounded Power Configuration (wye
secondary)
L3
L2
L1
L3
L2
L1
E
L3
L2
L1
L3
L2
L1
2198-Exxxx-ERS
Servo Drives
L1C
L2C
Transformer (wye) Secondary
Mains AC Input
Power Connector
Bonded Cabinet Ground Bus
Ground Grid or Power
Distribution Ground
AC Line
Filter
Circuit
Protection
Feeder and branch short-circuit
protection is not illustrated.
Control AC Input
Power Connector
Circuit
Protection
ATTENTION:
The power system must be center-grounded wye
secondary configuration for Kinetix 5100 drives.
L3
L2
L1
L3
L2
L1
E
L3
L2
L1
L3
L2
L1
2198-Exxxx-ERS
Servo Drives
24V-
24V+
Transformer (wye) Secondary
Mains AC Input
Power Connector
Bonded Cabinet Ground Bus
Ground Grid or
Power Distribution Ground
AC Line
Filter
Circuit
Protection
Feeder and branch short-circuit
protection is not illustrated.
Control Input
Power Connector
24V DC
Power Supply
(customer supplied)
Содержание Allen-Bradley 2198-E1004-ERS
Страница 10: ...10 Rockwell Automation Publication 2198 RM004C EN P March 2022 Chapter 1 Migration Options Notes ...
Страница 36: ...36 Rockwell Automation Publication 2198 RM004C EN P March 2022 Chapter 2 Replacement Considerations Notes ...
Страница 56: ...56 Rockwell Automation Publication 2198 RM004C EN P March 2022 Chapter 4 Dimensions Cables and Wiring Notes ...