Figure 3 - Kinetix 300 Drive Digital Output Circuit
Figure 4 - Kinetix 5100 Digital Output Circuit
Analog Inputs
This section describes analog inputs for the Kinetix 300 and Kinetix 5100 servo
drives.
The Kinetix 300 drive analog reference input AIN1+ and AIN1- terminals
(IOD-24 and IOD-25) accepts up to a ±10V DC analog signal. This analog signal
is converted to a digital value with 12-bit resolution (11 bit plus sign). The total
reference voltage as seen by the drive is the voltage difference between the
AIN1+ and AIN1- terminals. If used in Single-ended mode, one of the analog
terminals must be connected to a voltage source while the other one must be
connected to ACOM. If used in Differential mode, the voltage source is
connected across AIN1+ and AIN1- and the driving circuit common, if
available, is connected to the drive Analog Common (ACOM) terminal.
OUT1-E
OUT1-C
Logic Power
GND
Kinetix 300 Drive
OUTPUTx–
24V DC
R
OUTPUTx–
24V DC
An external 24V DC power supply is
required to energize the load.
An external 24V DC power supply is
required to energize the inductive load.
Make sure the polarity of the diode is
correct or it can damage the servo drive.
Kinetix 5100 Servo Drive
Kinetix 5100 Servo Drive
Содержание Allen-Bradley 2198-E1004-ERS
Страница 10: ...10 Rockwell Automation Publication 2198 RM004C EN P March 2022 Chapter 1 Migration Options Notes ...
Страница 36: ...36 Rockwell Automation Publication 2198 RM004C EN P March 2022 Chapter 2 Replacement Considerations Notes ...