44
Rockwell Automation Publication 2198-RM004C-EN-P - March 2022
Chapter 3 Connectors
Safe Torque Off Connector
Both the Kinetix 300 drive and Kinetix 5100 drive have a Safe Torque Off (STO)
connector. The STO pinouts are different between the two drives. See
for a comparison of the two connectors. See the Kinetix 300
EtherNet/IP™ Indexing Servo Drives User Manual, publication
for information on STO with the Kinetix 300 drive. See the Kinetix 5100 Single-
axis EtherNet/IP Servo Drives User Manual, publication
for
information on STO with the Kinetix 5100 drive.
Figure 17 - STO Connector Assignment Comparison
Table 49 - STO Connector Assignment Comparison
Kinetix 300 Servo Drive
Kinetix 5100 Servo Drive
Pin
Signal
Description
Signal
Description
1
+24V DC control
+24V DC output from the
drive
SB+
used for
2
Control COM
+24V DC output common
SB-
used for jumper -
3
Safety Status
Safety status
S1
STO 1 +
4
Safety Input 1
Safety input 1 (+24V DC to
enable)
S1C
STO 1 -
5
Safety COM
Safety common
S2
STO 2 +
6
Safety Input 2
Safety input 2 (+24V DC to
enable)
S2C
STO 2 -
7
—
—
SS+
Safety Status or Feedback
8
—
—
SS-
Safety Status or Feedback
1 2 3 4 5 6
SB–
S1C
S2C
SS–
SB+
S1
S2
SS+
Kinetix 300 Drive
STO Connector
Kinetix 5100 Drive
STO Connector