Rockwell Automation Publication 2198-RM004C-EN-P - March 2022
19
Chapter 2 Replacement Considerations
Table 16 - Kinetix 5100 Power Specifications (480V nom three-phase, continued)
Attribute
2198-E4030-ERS
2198-E4055-ERS
2198-E4075-ERS
2198-E4150-ERS
AC input voltage
342…528V rms, three-phase (380/480V nom)
AC input frequency
47…63 Hz
Mains AC input current
(1)
Nom (rms) 380V input (three-phase)
Max inrush (0-pk) 380V input
Nom (rms) 480V input (three-phase)
Max inrush (0-pk) 480V input
9.96 A
9.43 A
7.91 A
11.91 A
16.825 A
9.43 A
13.35 A
11.91 A
23.664 A
9.43 A
18.78 A
11.91 A
36.855 A
28.28 A
29.25 A
35.73 A
Control power input voltage
21.6…26.4V DC,
24V DC nom
Control power input current @ 24V DC
(2)
Control power in-rush current @ 24V DC
1.77 A
DC
4.97 A
DC
2.03 A
DC
3.24 A
DC
4.43 A
DC
3.40 A
DC
Continuous output current (rms)
13.95 A
24.8 A
31.0 A
41.26 A
Continuous output current (0-pk)
19.73 A
35.07 A
43.84 A
58.35 A
Peak output current (rms)
(3)
26.08 A
37.65 A
53.32 A
70.14 A
Peak output current (0-pk)
36.88 A
53.24 A
75.39 A
99.18 A
Line loss ride through
20 ms
Continuous output power
3.0 kW
5.5 kW
7.5 kW
15.0 kW
Internal shunt on
760V
Internal shunt off
Internal shunt resistor
—
—
—
—
Internal shunt power
—
—
—
—
Bus undervoltage
282V
Bus overvoltage
820V
Bus capacitance
560 µF
1120 µF
1640 µF
2500 µF
Capacitive energy absorption
38.2 J
76.3 J
111.7 J
170.3 J
Short-circuit current rating
5,000 A (rms) symmetrical
(1)
Kinetix 5100 drive modules are limited to 1 AC mains power cycling per minute.
(2) Kinetix 5100 drive modules are limited to 1 control power cycling every 20 seconds.
(3) Peak RMS current allowed for up to 1.8 seconds.
Table 17 - Kinetix 5100 Drive Control Power Specifications - 200V-class
Attribute
2198-E1004-
ERS,
2198-E1007-
ERS,
2198-E1015-
ERS,
2198-E1020-
ERS
2198-E2030-
ERS
2198-E2055-
ERS
2198-E2075-
ERS
2198-E2150-
ERS
Control power input voltage
120V AC input power
95…132V rms, 120V AC nom, single-phase
—
—
—
—
Control power input voltage
200…230V AC input power
170…253V rms, 200…230V AC nom, single-phase
Control power input current
Nom (rms) 120V input max
inrush (0-pk)
0.34 A
15.80 A
0.38 A
18.20 A
0.38 A
19.20 A
0.63 A
19.20 A
—
—
—
—
Control power input current
Nom (rms) 230V input max
inrush (0-pk)
0.20 A
37.0 A
0.22 A
37.40 A
0.22 A
39.80 A
0.35 A
32.40 A
0.35 A
36.40 A
0.46 A
32.80 A
0.48 A
40.0 A
0.92 A
37.0 A