12
Rockwell Automation Publication 2198-RM004C-EN-P - March 2022
Chapter 2 Replacement Considerations
Kinetix 300 drives can be replaced with a Kinetix 5100 drive of similar, or in
some cases greater, output current capability.
The Kinetix 5100 drives with similar current ratings require less or equivalent
physical space than the Kinetix 300 drives.
Factors that affect the redesign effort include the following considerations:
•
Drive sizing (ratings and physical)
•
Dimension comparison
•
Drive interconnects and cabling
•
Communication (Serial, USB, or EtherNet/IP™)
•
Accessories
Drive Sizing
This section lists the Kinetix 300 servo drives and the suggested Kinetix 5100
servo drives. The tables show the output ratings and dimensional differences.
Information in this migration guide is based on the drive combinations that
are shown in
.
Nominal Voltage and Output Current Comparison
compares the Output Current of the Kinetix 300 and Kinetix 5100
drives for a given input voltage. Review
to be sure that the replacement
drive can deliver the required peak and continuous current to the motor.
Table 5 - Suggested Kinetix 5100 Replacement Drives by Output Current
Kinetix 300 drive
Kinetix 5100 drive
Cat. No.
Voltage Range
Nominal
Voltage
Range
Continuous
Output
Current
A rms
(0-pk)
Peak
Output
Current
A rms
(0-pk)
Cat. No.
Voltage Range
Nominal Voltage
Range
Continuous
Output
Current
A rms
(0-pk)
Peak Output
Current
A rms
(0-pk)
2097-V31PR0
70…132V, 1 PH
(120V nom),
voltage-doubler
mode
80…264V, 1 PH
(120/240V nom)
1 PH,
120/240V
2 (2.8)
6.0 (8.5)
2198-E1004-ERS
95…132V, 1 PH
170…253V, 1 PH/3 PH
120V, 1 PH
230V, 1 PH/3 PH
2.60 (3.68)
6.5 (9.19)
2097-V31PR2
1 PH,
120/240V
4 (5.7)
12.0 (17.0)
2198-E1007-ERS
95…132V, 1 PH
170…253V, 1 PH/3 PH
120V, 1 PH
230V, 1 PH/3 PH
5.10 (7.21)
15.41 (21.79)
2097-V32PR0
80…264V, 1 PH
(240V nom)
1 PH, 240V
2 (2.8)
6.0 (8.5)
2198-E1004-ERS
95…132V, 1 PH
170…253V, 1 PH/3 PH
120V, 1 PH
230V, 1 PH/3 PH
2.60 (3.68)
6.5 (9.19)
2097-V32PR2
1 PH, 240V
4 (5.7)
12.0 (17.0)
2198-E1007-ERS
95…132V, 1 PH
170…253V, 1 PH/3 PH
120V, 1 PH
230V, 1 PH/3 PH
5.10 (7.21)
15.41 (21.79)
2097-V32PR4
1 PH, 240V
8 (11.3)
24.0 (33.9)
2198-E1015-ERS
95…132V, 1 PH
170…253V, 1 PH/3 PH
120V, 1 PH
230V, 1 PH/3 PH
7.9 (11.17)
23.7 (33.51)
2097-V33PR1
80…132V, 1 PH
(120V nom)
80…264V, 1 PH
(240V nom)
80…264V, 3 PH
(240V nom)
1 PH/3 PH,
240V
2 (2.8)
6.0 (8.5)
2198-E1004-ERS
95…132V, 1 PH
170…253V, 1 PH/3 PH
120V, 1 PH
230V, 1 PH/3 PH
2.60 (3.68)
6.5 (9.19)
2097-V33PR3
1 PH/3 PH,
240V
4 (5.7)
12.0 (17.0)
2198-E1007-ERS
95…132V, 1 PH
170…253V, 1 PH/3 PH
120V, 1 PH
230V, 1 PH/3 PH
5.10 (7.21)
15.41 (21.79)
2097-V33PR5
1 PH/3 PH,
240V
8 (11.3)
24.0 (33.9)
2198-E1015-ERS
95…132V, 1 PH
170…253V, 1 PH/3 PH
120V, 1 PH
230V, 1 PH/3 PH
7.9 (11.17)
23.7 (33.51)
2097-V33PR6
1 PH/3 PH,
240V
12 (17.0)
36.0 (50.9)
2198-E1020-ERS
95…132V, 1 PH
170…253V, 1 PH/3 PH
120V, 1 PH
230V, 1 PH/3PH
13.4 (18.95)
53.03 (74.98)
2097-V34PR3
320…528V, 3 PH
(480V nom)
3 PH, 480V
2 (2.8)
6 (8.5)
2198-E4007-ERS
342…528V, 3PH
(480V nom)
3 PH, 480V, 3PH
3.19 (4.51)
8 (11.31)
2097-V34PR5
3 PH, 480V
4 (5.7)
12 (17)
2198-E4015-ERS
3 PH, 480V, 3PH
6.05 (8.56)
15.11 (21.36)
2097-V34PR6
3 PH, 480V
6 (8.5)
18 (25.5)
2198-E4020-ERS
3 PH, 480V, 3PH
7.42 (10.49)
20.78 (29.38)
Содержание Allen-Bradley 2198-E1004-ERS
Страница 10: ...10 Rockwell Automation Publication 2198 RM004C EN P March 2022 Chapter 1 Migration Options Notes ...
Страница 36: ...36 Rockwell Automation Publication 2198 RM004C EN P March 2022 Chapter 2 Replacement Considerations Notes ...
Страница 56: ...56 Rockwell Automation Publication 2198 RM004C EN P March 2022 Chapter 4 Dimensions Cables and Wiring Notes ...