Rockwell Automation Publication 2198-RM004C-EN-P - March 2022
11
Chapter
2
Replacement Considerations
Replacing a Kinetix® 300 drive with a Kinetix 5100 drive can require some
system design changes:
•
Review the hardware and software design of the existing Kinetix 300
system.
•
Compare these designs to the hardware and software specifications for
the Kinetix 5100 drives.
This publication highlights the major similarities and differences between the
Kinetix 300 drives and the Kinetix 5100 drives. Additional criteria not covered
in this publication can also impact your application. Review this publication to
evaluate the Kinetix 5100 drives for your needs.
Design considerations:
•
Upload the programmable logic controller (PLC) programs and
determine what you can use for the new system.
•
See the System Design for Control of Electrical Noise Reference Manual,
publication
, for information on the concept of high-
frequency (HF) bonding, the Ground Plane principle, and electrical noise
reduction.
•
Verify that your current motor is compatible.
•
Verify that the motor power and feedback cable length in your existing
system does not exceed the maximum cable length for the new system.
•
Verify that the drive size is compatible.
•
Verify that the drive dimensions are compatible.
•
Verify that the drive connections and connectors are acceptable or
compatible.
Selecting a Replacement
Drive
There are a number of different factors that affect the selection of a
replacement servo drive and the system redesign effort. Drive sizing is the
primary factor in selecting a replacement servo drive. To identify the correct
replacement drive size, compare the continuous and peak output current
ratings.
WARNING:
Because of the variety of uses for the products described in this
publication, those responsible for the application and use of these
products must satisfy themselves that all necessary steps have been taken
to make sure that each application and use meets all performance and
safety requirements, including any applicable laws, regulations, codes, and
standards. In no event will Rockwell Automation be responsible or liable for
indirect or consequential damage resulting from the use or application of
these products.