35
Inner Shaft Installation
Open the bleed tool hose clamp. Hydraulic fluid should not drain out of
the hose.
If hydraulic fluid drains from the hose, air has entered the IFP tube
during IFP installation, and the IFP
removal
and
installation
processes
must be repeated.
Hold the shaft in place and carefully slide the seal head down the shaft
into the upper post. Thread the seal head into the upper post by hand
until it stops.
NOTICE
Do not push the inner shaft into the upper post. Fluid will be forced out
of the IFP tube through Reverb™ bleed tool hose. If fluid drains out of
the hose, the IFP
removal
and
installation
processes must be repeated.
A small amount of fluid may drip from the bleed tool as the seal head
is threaded into the upper post. This is normal.
Tighten the seal head to 28 N•m (250 in-lb).
Use a shop towel to wipe away any excess fluid.
NOTICE
Do not scratch the inner shaft with the wrench as this is a critical
sealing surface. Surface scratches can cause leaks and reduce
performance.
4
Reverb Post Bleed Tool
5
6
23 mm
28 N•m (250 in-lb)