8.0 Supplementary Information
M303
Set ambient temperature control parameters P, F, D, B, T, U
This command is only really for advanced use, as these values should never need to be changed.
It is used to adjust the control parameters for the ambient fan.
M500
Store parameters to EEPROM
This writes any new settings to the firmware. If not stored using M500, settings will be lost when
the power is cycled.
M502
Revert to default parameter values
This resets the firmware parameters to the factory defaults. Save using M500.
M503
Show settings
This outputs the current firmware settings to the console.
M510
Invert axis [X Y Z E D B]
Where 0=false, 1=true.
This command is only really for advanced use, as these values should
never need to be changed. It causes all motion on the specified axis to occur in the opposite
direction.
M520
Set axis travel [X Y Z]
This command is only really for advanced use, as these values should never need to be changed.
It specifies the length of each axis in mm.
M526
Invert switch inputs [X Y Z Z+ E D B]
Where 0=false, 1=true.
This command is only really for advanced use, as these values should
never need to be changed. It inverts the output from the specified switch (X, Y, Z and Z+ endstops,
extruder 1 and 2 output switches, nozzle homing switch).
M527
Set home distance [X Y Z E D B]
This command is only really for advanced use, as these values should never need to be changed.
For X, Y and Z, it specifies the distance the head can move beyond the point that the endstop
is activated, and therefore it defines the homing speed. For E and D, this defines the distance
filament travels from the extruder output switch to the entry point of the head along the Bowden
tube.
M906
Set motor current [X Y Z E D B]
This command is only really for advanced use, as these values should never need to be changed.
It sets the current of the specified motor in Amps. e.g. M906 X1.2 would set the X motor driver
output to 1.2A.
M907
Set motor hold current (Amps) [X Y Z E D B]
This command is only really for advanced use, as these values should never need to be changed.
It sets the hold current of the specified motor in Amps. e.g. M907 Z0.3 would set the Z motor driver
hold output to 0.3A.
M908
Set extruder motor reduced current (Amps) [E D]
This command is only really for advanced use, as these values should never need to be changed.
This sets the current of the extruder motor when a G36 command is issued - move until slip.
This helps prevent ‘stripping’ of the filament by causing the motor to skip rather than the teeth
skipping on the filament. e.g M908 E0.7 would set the extruder 1 slip current to 0.7A.
M909
Set filament slip detection threshold (mm) [S]
This command defines the difference between how far filament has been told to travel, and how
far it travels in order to trigger a filament slip error. i.e. if this value is set to 2mm, and the filament is
told to travel 10mm, a error will be triggered if it moves <8mm.
Содержание 3d printer
Страница 1: ...www cel robox com UserGuide including AutoMaker Version 1 1 ...
Страница 6: ...1 0 1 0 Introduction ...
Страница 19: ...Overview 2 0 ...
Страница 25: ...Getting Started 3 0 ...
Страница 34: ...Using Robox 4 0 ...
Страница 42: ...AutoMaker Software 5 0 ...
Страница 77: ...77 77 www cel robox com 5 0 AutoMaker Software ...
Страница 78: ...Finishing Parts 6 0 ...
Страница 82: ...Calibration and Maintenance 7 0 ...
Страница 99: ...99 99 www cel robox com 7 0 Calibration and Maintenance ...
Страница 100: ...Supplementary Information 8 0 ...
Страница 122: ... 2014 CEL Technology Ltd All rights reserved RBX01 ACC UM ...