24 • VOC Pro Transmitter
Operation
WARNING: Do not remove the sensor housing cap or enclosure lid while the circuits are
energized unless the area is determined to be non-hazardous. Keep the sensor
housing cap and enclosure lid tightly closed during operation.
Normal Operating Mode
While in normal operating mode, the VOC Pro continuously samples the air and updates the
measured concentration of the target gas on the display screen. The display, when in normal
operation, appears as shown below.
Manual Reset for Activated Latching Alarms
Relay alarms set to latching will not deactivate until the alarms are manually reset at the
device. This includes Alarm 1 and Alarm 2 indicator LEDs and optional wired relays. When
latching alarms have been activated, refer to the following instructions for how to manually
deactivate the alarms on your device:
1. Verify that the gas level reading is below the alarm level setting.
2. Press the MENU button to deactivate latching alarm(s).
NOTE:
The gas level reading MUST be below the alarm level setting before the alarm can be
deactivated. Press the MENU button ONLY once to deactivate the latching alarm(s).
Pressing the MENU button more than once will activate and open the Operation
Settings menu. The alarms will NOT activate, even in the presence of gas, until you
have exited the menu mode for approximately 1 minute.
Reading above full scale
(4-20 mA output is 25 mA)
1. Measured gas concentration (reading)
2. Gas concentration unit of measure
3. Sensor element gas type