4-18
IMSBR10-E1
Item
Description
Reference
Section
Periodic printout
Computed value
Scale
Channel number
or tag
Recording color
Mar.31.2004!
15:50*
1 1.000V
A -100.00UNIT
-200.00 200.00
A
UNIT
RED
50mm/h_
• Type of computed values to be printed/disable periodic printout
7.8
Common with measurement channels.
• If Report is selected, use Math > Print2 in Basic Setting mode to select
9.15
the report data type.
• Printout interval
7.8
Set Math > TLOG > Timer No. in Setting mode to Periodic.
The interval is common with measurement channels.
• Turn On/Off periodic printout for each channel
9.9
Use Math > Aux > Print out > Periodic in Setting mode to enable/disable the
periodic printout for each computation channel.
• Scale printout and recording color printout (pen model)
7.7
Common with measurement channels.
Periodic printout using TLOG timer (dedicated to computation channels)
Computed value
Scale
Channel number
or tag
Recording color
Timer number
Mar.31.2004!
15:50*
TAG-00A 100.00UNITA
B 1.0
-200.00
200.00
TAG-00A
UNITA
RED
TLOG1
• Use Math > Timer (TLOG) in Basic Setting mode to set the printout interval.
9.12
• Use Math > Timer (TLOG) > Print in Basic Setting mode to turn the printout On.
9.12
• Use Math > Aux > Print out > Periodic in Setting mode to enable/disable the
9.9
periodic printout for each computation channel.
• Set Math > TLOG > Timer No. in Setting mode to set the timer used on each
9.6
computation channel.
• Scale printout and recording color (pen model)
Common with periodic printout.
Alarm occurrence/release printout
Common with measurement channels.
7.7
Tag
• Channel/tag selection
7.7
Common with measurement channels.
• Tag name
9.10
Use Math > Aux > Tag in Setting mode to set the tag name.
Bar graph display mode
Use Math > Bar graph in Basic Setting mode to set the bar graph display mode.
9.16
Procedure when computed results are in error
Use Math > Error data in Basic Setting mode to set the procedure taken when the
9.17
computed results are in error.
Remote control function (/R1 option)
Item
Description
Reference
Section
Remote control function (/R1 option)
• Assign functions to the remote control input terminals
7.18
Use Remote in Basic Setting mode to set the function to be assigned to the
remote control input terminal.
• Secondary chart speed
6.9
If “chart speed switching” is assigned, use Aux > Chart 2 in Setting mode to
set the secondary chart speed.
4.4 Function Setup Guide