Rinnai
44
RDV 600_700 OIM
ABNORMAL FLAME PATTERN
Each Rinnai Gas Fire has a distinct flame pattern. The flame should look the same every time you start your heater,
after an initial warm up period of approximately 15 minutes.
Abnormal flame performance and/or pattern can indicate a problem with your heater, such as blocked gas injectors,
incorrectly installed / inadequate flue system or the Ceramic logs / stones and or burn media may have shifted from
when the heater was first installed.
There are some warning signs that could indicate a problem. If any of the signs below occur, please contact Rinnai.
Key signs of abnormal flame performance:
• Appliance turns ‘OFF’ soon after start up and does not relight.
• Flame appears overly orange-yellow.
• Flame appears either very short or very long.
• Flame only burns part way across the burner.
• Severe soot building up on the inside of the glass and logs.
• Continuous unusual smell from the appliance.
• Continued difficulty or delay in establishing a flame.
Be advised that appliances incorporating a live fuel effect, and designed to operate with luminous
flames, may exhibit slight carbon deposition, this is normal operation.
NORMAL FLAME PATTERN
ABNORMAL FLAME PATTERN
SOOT BUILD UP
NOTE
COMPLETING HEATER INSTALLATION