Rinnai
24
RDV 600_700 OIM
HEATER ENGINE - GENERAL INSTALLATION
GAS SUPPLY
Installation of consumer piping
The gas supply (consumer piping), termination is inside the heater and enters
through the rear of the appliance.
Refer to the dimensional drawings on page 21 for appliance gas inlet location and
other relevant dimensions.
Mark off the location for the vertical centre line
of the heater enclosure (inbuilt
installations) or heater (freestanding installations).
To the right of the vertical centre line
, mark off both the vertical
and
horizontal
location for the gas supply penetration (consumer piping). For
measurements refer to the Gas Supply Dimension Table below.
The length of the gas supply (consumer piping) termination
is measured from
the front of the enclosure.
Gas Supply Dimension Table
Once the consumer piping has been terminated to the above requirements the
supplied flexible gas connection
may then be fitted.
Purging Gas Supply
Foreign materials and debris such as swarf, filings, etc.
MUST BE
purged/removed from the gas supply, failure to
do so may cause damage to the gas control valve causing it to malfunction.
Leak Testing The Connection
With the supplied plug
inserted into the end of the flexible gas connection leak test all joints.
Gas pipe sizing must consider the gas input to this appliance as well as all other gas appliances
in the premises. The gas meter and regulator must be specified for the total gas rate.
A suitable sizing chart such as the one in AS/NZS 5601 should be used.
Confirm correct gas type (see labels located on top or rear panels). Refer to local gas authority for
confirmation of gas type if you are in doubt.
RDV600ER
RDV700ER
265 mm to the right of the
appliance centre-line
312 mm to the right of the
appliance centre-line
18mm from base of enclosure
Consumer piping to be terminated 295 mm from the front of enclosure.
For masonry fireplace installations:
Gas supply dimension
MUST include the thickness of an infill
panel (when fitted). A standard Rinnai infill panel adds 2mm to the
front of the enclosure.
For false fireplace installations:
Gas supply dimension
MUST include the thickness of the
cladding to be used.
Use a soapy solution to test all gas connections. If a leak is present bubbles will form at the leak
point. When finished remove any residue with a rag. Prevent any soapy solution from coming in
contact with electrical components.
WARNING
IMPORTANT
FRONT OF ENCLOSURE
REAR OF
ENCLOSURE
4
1
2
Gas supply location
3
5
6
Gas supply pressure
to be 1.13 to 2.75 kPa
1
1
2
3
4
2
3
4
IMPORTANT
4
4
5
6
CAUTION
Содержание 650