background image

Copyright © 2008 by Lucky Distributing

  

 

 

Revision 2.0 updated 11/05/2008  

26

PROGRAMMING THE CONTROL 

If you intend to operate your stove manually, set it to 
the manual mode by pressing the ENTER button 
until the display no longer reads either “SB” or “TM”.

 
During start-up, the stove will read “ST” on the first 
display line, and “21” on the second display line. 
“ST” stands for start-up and “21” is the remaining 
start-up time in minutes (the time display will 
decrease as the start-up progresses).  
 
During the start-up cycle, only the auger and 
combustion fan operate with the combustion fan 
gradually increasing in speed.  The convection fan 
will turn on at the end of the start-up cycle. 
 

NOTE:  

As long as the stove is running, whether in 

the start-up mode, cleaning cycle, in normal 
operation, or while operating under the timed mode, 
you can increase or decrease the heat output level 
at any time by pressing the 

+

 

or “

“ keys.   

 

If the stove needs to be turned off at any time, push 
the ON/OFF button and the stove will immediately 
begin the shut-down process.  Complete shut-down 
takes a total of eight minutes.  The stove may 
remain hot for several hours after turning off. 
 
If the stove is running in timed mode when the 
power button is pushed, the schedule will resume at 
the next programmed interval. 

Содержание INTEGRA II

Страница 1: ...Copyright 2008 by Lucky Distributing Revision 2 0 updated 11 05 2008 1...

Страница 2: ...ey Word Abbreviations 32 User Notes 33 WARRANTY Warranty 35 Warranty Registration Card 36 SAFETY NOTICE IF THIS WOOD PELLET STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOLL...

Страница 3: ...today s marketplace Unique designs and emphasis on quality performance and superior workmanship have made us a leading stove manufacturer in Europe State of the art processes such as robotic welding...

Страница 4: ...or freshen up a fire in this stove Keep these flammable liquids well away from this stove when it is in use Build up of dust soot or creosote in the chimney connector and in the exhaust vent can cause...

Страница 5: ...time when the stove is running Keep hands and fingers away from auger at all times as contact with auger may cause personal injury DO NOT ABUSE THE DOOR GLASS USE CARE NOT TO STRIKE THE GLASS WITH OT...

Страница 6: ...Copyright 2008 by Lucky Distributing Revision 2 0 updated 11 05 2008 6 OMNI SAMPLE LABEL FOR INTEGRA PELLET STOVE INSERT...

Страница 7: ...Copyright 2008 by Lucky Distributing Revision 2 0 updated 11 05 2008 7 OMNI SAMPLE LABEL FOR INTEGRA PELLET STOVE INSERT...

Страница 8: ...period DC Voltage Side 1 HAL IC Combustion Motor Regulator silver bullet looking item mounted just above the air intake tube There is another lead on this component that is also attached to the combu...

Страница 9: ...8 1 2 Depth inches 25 3 4 Weight lbs 258 Exhaust Outlet 3 Heating Capacity 7 000 to 44 000 BTUs Fuel Consumption 1 5 lbs per hour Pellet Hopper Capacity 99lbs Power Supply 110 V 60 Hz Average Electric...

Страница 10: ...9 10 11 12 Figure 1 01 Ceramic Side Glass part Z14847 02 Ceramic Front Glass part Z14846 03 Cast Iron Door 04 Door Handle Bolt 05 Door Handle 06 Auger Cover 07 Heat Shield 08 Rear Heat Exchanger Acces...

Страница 11: ...2 15 Hopper Cover 16 Hopper Lid Fill Door 17 Air Sensor 18 Top Grill 19 Ash Pan 20 Burn Pot 21 Lower Cast Wall 22 Lower Cast Wall Gasket 23 Upper Cast Wall 24 High Limit Switch 25 Adjustable Door Lat...

Страница 12: ...ig 2 Figure 3 24 Power Cord 28 Flue Adapter 29 Connecting Band 30 Low Limit Switch 31 Low Limit Gasket 32 Combustion Motor Housing 33 Combustion Motor Fan 34 Convection Fan 35 Upper Door Hinge 36 Lowe...

Страница 13: ...the power resumes In this setting the stove will not turn itself back on NOTE During a power failure smoke can escape from the stove This is normal in a power outage If this occurs open windows and do...

Страница 14: ...will not be a hazard to people overheat combustible structures or enter into any building The total length of horizontal vent must not exceed five feet The PL vent exhaust system must be installed an...

Страница 15: ...mmodate installation of the stove Exceptions Masonry or steel including the damper place may be removed from the smoke shelf and adjacent damper frame if necessary to accommodate a chimney liner provi...

Страница 16: ...ntle 12 Shroud 29 x 42 min 5 2 Outside wall Listed wall thimble Listed end cap 7 min 6 min Floor protection to front of stove Raised hearth optional USG Micore and 24 guage sheet steel or equivelent F...

Страница 17: ...the back of the stove Floor protection of USG Micore and 24 guage sheet steel or equivelent is required Shroud Air tight seal Air tight seal Stove back Tee Clean out Trap Rain cap Seal chimney top wi...

Страница 18: ...ach 45 angle adds an effect of three additional feet of pipe length 4 venting is required in all installations at or above elevations of 2500 feet 4 venting is required in all installations where the...

Страница 19: ...s REQUIRED for mobile home installations 2 Only metal pipe with a minimum two inch diameter is approved for use as an outside air connection straight or flexible PVC pipe or aluminum pipe is NOT appro...

Страница 20: ...e same process as wood rotting by itself Rotting wood as well as burning wood releases CO2 that trees need to grow and therefore burning wood has no impact on the CO2 cycle Heating with pellets means...

Страница 21: ...ommended that you use the lowest ash content fuel available Using fuel with 3 ash content may require that the stove be cleaned as often as every one to two days Fuel with 1 ash content may only requi...

Страница 22: ...forming deposits during combustion Silica is actually sand and is present in all pellet fuels along with a variety of other impurities When clinkering takes place these hard substances tend to accumul...

Страница 23: ...en each of the three different operating modes Manual Mode press the power button to turn the unit on and off Automatic or Timed Mode TM runs according to a schedule that you determine Standby Mode SB...

Страница 24: ...by pressing ENTER NOTE Start and end times are in military format displays as 0 for midnight through 23 for 11pm The display should now read E1 for the ending time of the first heating period on Mond...

Страница 25: ...every 5 and 300 minutes The frequency of how often the cleaning cycle should run will vary depending upon pellet quality heat output settings availability of outside air and the natural ventilation o...

Страница 26: ...n fan operate with the combustion fan gradually increasing in speed The convection fan will turn on at the end of the start up cycle NOTE As long as the stove is running whether in the start up mode c...

Страница 27: ...arranty Listed below are recommended cleaning intervals and procedures for cleaning the user serviceable areas of your pellet stove Component Interval Heat Exchanger Baffle Tubes once daily and every...

Страница 28: ...remove the three screws securing the lower cast plate Once the screws are removed the plate should pull away from the back of the stove Carefully lift the lower plate out and brush off any ash build u...

Страница 29: ...the colored accent panel is not necessary for cleaning A scraper rod tool was provided with your stove see image that is specifically intended for cleaning the exchanger baffle tubes The two scraper r...

Страница 30: ...animal hair can collect on the air sensor and cause the sensor to send false readings to the control system Check door seal by closing a dollar bill in all four sides of the door When pulling on the...

Страница 31: ...of fuel it may take two complete start up cycles for the stove to become fully operational This is due to the fact that it takes approximately 10 to 15 minutes for the auger path to re load with fuel...

Страница 32: ...Copyright 2008 by Lucky Distributing Revision 2 0 updated 11 05 2008 32 CONTROL FLOW CHART...

Страница 33: ...Sunday S1 S2 E1 E2 Start 1 Start 2 End 1 End 2 Heating start times heating end times for automatic TM mode PS Power Start Output value from the beginning of heating time in TM Mode PE Power End Output...

Страница 34: ...higher Fuel Type FU ______ use FU2 for altitude above 2000ft and or direct vent installations this function only available in software v1 33 and higher Cleaning Cycle CL ______ cleaning cycle frequen...

Страница 35: ...r 2 Name address and telephone number of the seller date and proof of purchase 3 Name address and telephone number of installer and date of installation 4 Serial number of the stove 5 Nature of defect...

Страница 36: ...Copyright 2008 by Lucky Distributing Revision 2 0 updated 11 05 2008 36...

Страница 37: ...Copyright 2008 by Lucky Distributing Revision 2 0 updated 11 05 2008 37...

Отзывы: