background image

Copyright © 2008 by Lucky Distributing

  

 

 

Revision 2.0 updated 11/05/2008  

23

BASIC OPERATION 

 

DO NOT start your stove until the venting 
installation is complete 
 
NOTE:  

Your pellet stove is exclusively for burning 

pellets made from wood of a controlled quality. 
Non-pelletized solid fuels (straw, corn, chopped 
matter, etc.) should not be used.  Failure to adhere 
to these guidelines will void your warranty. 
 

NOTE:  

When operated correctly, your pellet stove 

will not overheat.  Improper operation can shorten 
the life expectancy of the stove and its components.
 

ATTENTION

: Your stove’s automatic ignition 

system will not work properly if either the hopper lid 
or combustion door are open. 

 
CONTROL UNIT PROGRAMMING AND 
FUNCTION 

Your pellet stove is equipped with a modern 
programmable control board and control software. 
The owner can set all equipment functions via the 
control keypad which is found on the right hand side 
of the unit.  The control board and software should 
only be altered by trained specialists.  Improper or 
unauthorized changes to your stove, unless outlined 
in your owner’s manual, will void your warranty. 
 

Possible Operating Modes 

Pressing ENTER on the control panel enables the 
user to change between each of the three different 
operating modes. 
  

  Manual Mode - press the power button to 

turn the unit on and off. 

  Automatic or Timed Mode (TM) - runs 

according to a schedule that you determine. 

  Standby Mode (SB) - waiting for you to 

change to one of the other two modes by 
pressing the “Enter” button on the key-pad. 
No function, other than programming, can 
occur in this mode.   

 

Control Keypad 

 
All settings and functions can be regulated via this 
unit. 

 

 

DISPLAY BOX 

Displays the operating modes in illuminated letters 
and numbers. 
 

MENU

 

Used for navigation in and to the different menu and 
sub-menu levels. 
 

ENTER

 

Used for navigation through the main menus (SB, 
ON, TM) and for confirming user entries. 
 

MINUS & PLUS

 

Used for lowering or increasing heat output levels 
and for changing program values. 
 

POWER  

Used for turning the unit on and off. 
 

TURNING YOUR STOVE ON AND OFF

 

To operate your stove manually, place it into 
manual mode (see the “POSSIBLE OPERATING 
MODES” section).   
 

Once in manual mode, the stove is turned on and off 
by pressing the power button.  Heat output is 
controlled by pressing the “+” and “–“ buttons.

 

Your RIKA pellet stove is equipped with an electronic ignition start-up system.  Starter fluids or gels are not necessary and 
should never be used.  Simply push the power button and the unit will ignite within a 12-minute period of time.  Total start-up 
cycle time is 21 minutes. 

Menu 

Minus

Power

Digital Display 

Enter 

Plus 

Содержание INTEGRA II

Страница 1: ...Copyright 2008 by Lucky Distributing Revision 2 0 updated 11 05 2008 1...

Страница 2: ...ey Word Abbreviations 32 User Notes 33 WARRANTY Warranty 35 Warranty Registration Card 36 SAFETY NOTICE IF THIS WOOD PELLET STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOLL...

Страница 3: ...today s marketplace Unique designs and emphasis on quality performance and superior workmanship have made us a leading stove manufacturer in Europe State of the art processes such as robotic welding...

Страница 4: ...or freshen up a fire in this stove Keep these flammable liquids well away from this stove when it is in use Build up of dust soot or creosote in the chimney connector and in the exhaust vent can cause...

Страница 5: ...time when the stove is running Keep hands and fingers away from auger at all times as contact with auger may cause personal injury DO NOT ABUSE THE DOOR GLASS USE CARE NOT TO STRIKE THE GLASS WITH OT...

Страница 6: ...Copyright 2008 by Lucky Distributing Revision 2 0 updated 11 05 2008 6 OMNI SAMPLE LABEL FOR INTEGRA PELLET STOVE INSERT...

Страница 7: ...Copyright 2008 by Lucky Distributing Revision 2 0 updated 11 05 2008 7 OMNI SAMPLE LABEL FOR INTEGRA PELLET STOVE INSERT...

Страница 8: ...period DC Voltage Side 1 HAL IC Combustion Motor Regulator silver bullet looking item mounted just above the air intake tube There is another lead on this component that is also attached to the combu...

Страница 9: ...8 1 2 Depth inches 25 3 4 Weight lbs 258 Exhaust Outlet 3 Heating Capacity 7 000 to 44 000 BTUs Fuel Consumption 1 5 lbs per hour Pellet Hopper Capacity 99lbs Power Supply 110 V 60 Hz Average Electric...

Страница 10: ...9 10 11 12 Figure 1 01 Ceramic Side Glass part Z14847 02 Ceramic Front Glass part Z14846 03 Cast Iron Door 04 Door Handle Bolt 05 Door Handle 06 Auger Cover 07 Heat Shield 08 Rear Heat Exchanger Acces...

Страница 11: ...2 15 Hopper Cover 16 Hopper Lid Fill Door 17 Air Sensor 18 Top Grill 19 Ash Pan 20 Burn Pot 21 Lower Cast Wall 22 Lower Cast Wall Gasket 23 Upper Cast Wall 24 High Limit Switch 25 Adjustable Door Lat...

Страница 12: ...ig 2 Figure 3 24 Power Cord 28 Flue Adapter 29 Connecting Band 30 Low Limit Switch 31 Low Limit Gasket 32 Combustion Motor Housing 33 Combustion Motor Fan 34 Convection Fan 35 Upper Door Hinge 36 Lowe...

Страница 13: ...the power resumes In this setting the stove will not turn itself back on NOTE During a power failure smoke can escape from the stove This is normal in a power outage If this occurs open windows and do...

Страница 14: ...will not be a hazard to people overheat combustible structures or enter into any building The total length of horizontal vent must not exceed five feet The PL vent exhaust system must be installed an...

Страница 15: ...mmodate installation of the stove Exceptions Masonry or steel including the damper place may be removed from the smoke shelf and adjacent damper frame if necessary to accommodate a chimney liner provi...

Страница 16: ...ntle 12 Shroud 29 x 42 min 5 2 Outside wall Listed wall thimble Listed end cap 7 min 6 min Floor protection to front of stove Raised hearth optional USG Micore and 24 guage sheet steel or equivelent F...

Страница 17: ...the back of the stove Floor protection of USG Micore and 24 guage sheet steel or equivelent is required Shroud Air tight seal Air tight seal Stove back Tee Clean out Trap Rain cap Seal chimney top wi...

Страница 18: ...ach 45 angle adds an effect of three additional feet of pipe length 4 venting is required in all installations at or above elevations of 2500 feet 4 venting is required in all installations where the...

Страница 19: ...s REQUIRED for mobile home installations 2 Only metal pipe with a minimum two inch diameter is approved for use as an outside air connection straight or flexible PVC pipe or aluminum pipe is NOT appro...

Страница 20: ...e same process as wood rotting by itself Rotting wood as well as burning wood releases CO2 that trees need to grow and therefore burning wood has no impact on the CO2 cycle Heating with pellets means...

Страница 21: ...ommended that you use the lowest ash content fuel available Using fuel with 3 ash content may require that the stove be cleaned as often as every one to two days Fuel with 1 ash content may only requi...

Страница 22: ...forming deposits during combustion Silica is actually sand and is present in all pellet fuels along with a variety of other impurities When clinkering takes place these hard substances tend to accumul...

Страница 23: ...en each of the three different operating modes Manual Mode press the power button to turn the unit on and off Automatic or Timed Mode TM runs according to a schedule that you determine Standby Mode SB...

Страница 24: ...by pressing ENTER NOTE Start and end times are in military format displays as 0 for midnight through 23 for 11pm The display should now read E1 for the ending time of the first heating period on Mond...

Страница 25: ...every 5 and 300 minutes The frequency of how often the cleaning cycle should run will vary depending upon pellet quality heat output settings availability of outside air and the natural ventilation o...

Страница 26: ...n fan operate with the combustion fan gradually increasing in speed The convection fan will turn on at the end of the start up cycle NOTE As long as the stove is running whether in the start up mode c...

Страница 27: ...arranty Listed below are recommended cleaning intervals and procedures for cleaning the user serviceable areas of your pellet stove Component Interval Heat Exchanger Baffle Tubes once daily and every...

Страница 28: ...remove the three screws securing the lower cast plate Once the screws are removed the plate should pull away from the back of the stove Carefully lift the lower plate out and brush off any ash build u...

Страница 29: ...the colored accent panel is not necessary for cleaning A scraper rod tool was provided with your stove see image that is specifically intended for cleaning the exchanger baffle tubes The two scraper r...

Страница 30: ...animal hair can collect on the air sensor and cause the sensor to send false readings to the control system Check door seal by closing a dollar bill in all four sides of the door When pulling on the...

Страница 31: ...of fuel it may take two complete start up cycles for the stove to become fully operational This is due to the fact that it takes approximately 10 to 15 minutes for the auger path to re load with fuel...

Страница 32: ...Copyright 2008 by Lucky Distributing Revision 2 0 updated 11 05 2008 32 CONTROL FLOW CHART...

Страница 33: ...Sunday S1 S2 E1 E2 Start 1 Start 2 End 1 End 2 Heating start times heating end times for automatic TM mode PS Power Start Output value from the beginning of heating time in TM Mode PE Power End Output...

Страница 34: ...higher Fuel Type FU ______ use FU2 for altitude above 2000ft and or direct vent installations this function only available in software v1 33 and higher Cleaning Cycle CL ______ cleaning cycle frequen...

Страница 35: ...r 2 Name address and telephone number of the seller date and proof of purchase 3 Name address and telephone number of installer and date of installation 4 Serial number of the stove 5 Nature of defect...

Страница 36: ...Copyright 2008 by Lucky Distributing Revision 2 0 updated 11 05 2008 36...

Страница 37: ...Copyright 2008 by Lucky Distributing Revision 2 0 updated 11 05 2008 37...

Отзывы: